System Interface Terminals A And B - Festo EduTrainer 8071407 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

10.2.2 System interface terminals A and B

Simultaneous use of 4 mm cables and the system interfaces is not recommended!
15-pin system interfaces A and B function in the digital mode only, therefore the toggle switch must be
switched from the relay to the digital output function. When the toggle switch is in the upper switch
position, the 24 V LED lights up. In this case, 24 V DC is applied to the top row of output connections
(connected with the red line). This is also indicated by an LED in this section of the panel. Each output is
decoupled with diodes. In the lower switch position, voltage is enabled at terminals A and B.
Warning!
Only 24 V DC control signals with max. 500 mA can be connected.
Pin
Terminal A
Terminal B
1
I1
2
Q1
3
I2
4
Q2
5
I3
6
Q3
7
I4
8
Q4
9
AI0
10
AI1
11
A
Out
12
VCC
13
14
GND
GND
15
© Festo Didactic 8071396
I5
The number of available inputs
and outputs depends on the
Q5
mini control system used and
its allocations.
I6
Q6
I7
Q7
I8
Q8
AI0
Only via optional wiring of the
terminal strip.
AI1
A
Out
Corresponds to no more than
VCC
mini control system supply
voltage.
Mini Control Systems EduTrainer
Internal allocation of the analog
terminal
Pin
Terminal A
Terminal B
1
AI0
2
AI1
3
A
Out
4
AI0
5
AI1
6
A
7
VCC
8
9
GND
10
®
Out
39