Devices with an earth terminal must always be grounded.
If an earth connection (green-yellow laboratory socket) is available, it must always be
connected to protective earth. Protective earth must always be connected first (before voltage),
and must always be disconnected last (after voltage).
Some devices have a high leakage current. These devices must be additionally grounded
with a protective earth conductor.
When replacing fuses, use specified fuses only with the correct current ratings and tripping
characteristics.
The device is not equipped with an integrated fuse unless specified otherwise in the technical data.
Always pull on the plug when disconnecting connecting cables; never pull the cable.
Hazard-free operation of the device is no longer possible in the case of:
Visible damage
Malfunction
Incorrect storage
Incorrect transport
Switch off the power supply immediately.
Protect the device against inadvertent restart.