8

INSTALLATION

8.1

Safety instructions

DANGER!
Danger – high pressure in the equipment.
▶ Before loosening the lines and valves, turn off the pressure and vent the lines.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorised technicians only and with the appropriate tools.
Risk of injury from unintentional activation of the system and an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following assembly, ensure a controlled restart.
For control function I – Danger if pilot pressure fails.
For control function I control and resetting occur pneumatically. If the pressure fails, no defined position is
reached.
▶ To ensure a controlled restart, first pressurize the device with pilot pressure, then switch on the medium.
CAUTION!
Risk of injury due to a heavy device.
A heavy device can fall down during transport or during installation and cause injuries.
▶ Transport, install and dismantle a heavy device with the help of another person.
▶ Use appropriate tools.
NOTE!
Note the following when installing the device in the plant.
▶ The device and the relief bore must be accessible to allow inspection and maintenance work.
8.2

Installation position

The installation position of the diaphragm control valve varies depending on the valve body.
Installation for leakage detection
One of the bores in the diaphragm socket, for monitoring leakage, must be at the lowest point.
34