schmersal SRB 324ST/R V.3 Operating Instructions Manual
schmersal SRB 324ST/R V.3 Operating Instructions Manual

schmersal SRB 324ST/R V.3 Operating Instructions Manual

Advertisement

Quick Links

Operating instructions
Safety-monitoring module
EN
Operating instructions...................... pages 1 to 8
Translation of the original operating instructions
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2 Setting report SRB 324ST/R V.3 . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8.5 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1 About this document

1.1 Function

This operating instructions manual provides all the information you need
for the mounting, set-up and commissioning to ensure the safe operation
and disassembly of the safety-monitoring module. The operating instruc-
tions must be available in a legible condition and a complete version in
the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Elan
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability. Subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of inadequate or improper use or manipulations of
the safety-monitoring module, personal hazards or damage
to machinery or plant components cannot be excluded. The
relevant requirements of the standard EN 1088 must be
observed.
EN
SRB 324ST/R V.3
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 324ST/R V.3 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SRB 324ST/R V.3

  • Page 1 The information contained in this operating instructions manual is 5.2 Setting report SRB 324ST/R V.3 ......5 provided without liability.
  • Page 2 Operating instructions Safety-monitoring module SRB 324ST/R V.3 2.4 Technical data 1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from General data: defective mounting or failure to comply with this operating instructions Standards: IEC/EN 60204-1, EN 60947-5-1, manual.
  • Page 3 Operating instructions Safety-monitoring module SRB 324ST/R V.3 Switching capacity of 13-14, 23-24, 33-34 (STOP 0): 3 Mounting the safety contacts: max. 250 V, 8 A ohmic (inductive in case of suitable protective wiring); 3.1 General mounting instructions AC-15: 230 VAC / 6 A, Mounting: snaps onto standard DIN rails to EN 60715.
  • Page 4 • The DIP switches can be set when the operating voltage is on; button S1. however, in order for the setting to be saved in the SRB 324ST/R V.3, • Button S1 is located underneath the front cover of the safety- the voltage supply must be interrupted for approx.
  • Page 5 Operating instructions Safety-monitoring module SRB 324ST/R V.3 5.2 Setting report SRB 324ST/R V.3 8 Appendix This report regarding the setting of the device must be completed accordingly by the customer and enclosed in the technical manual 8.1 Wiring examples of the machine.
  • Page 6 Operating instructions Safety-monitoring module SRB 324ST/R V.3 8.3 Sensor configuration Dual-channel guard door monitoring circuit with interlocking device to EN 1088 (Fig. 15) Dual-channel control of a safety-related electronic (micro- • With at least one positive-break position switch processor-based) safety guard with p-type transistor outputs •...
  • Page 7 Operating instructions Safety-monitoring module SRB 324ST/R V.3 The connection of magnetic safety switches to the SRB Differentiated control with feedback circuit (Fig. 21) 324ST/R V.3 safety-monitoring module is only admitted • Suitable for increase in capacity or number of contacts by means when the requirements of the standard EN 60 947-5-3 of contactors or relays with positive-guided contacts.
  • Page 8 Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. Elan Schaltelemente GmbH & Co. KG Im Ostpark 2, D - 35435 Wettenberg Postfach 1109, D - 35429 Wettenberg Telefon:...

Table of Contents