schmersal SLB240 Operating Instructions Manual

schmersal SLB240 Operating Instructions Manual

Safety light barriers

Advertisement

Quick Links

Operating instructions
Safety light barriers
Operating instructions           pages 1 to 10
EN
Original
Content
1
About this document
11
Function                                            1
12
Target group: authorised qualified personnel                1
13
Explanation of the symbols used                         1
14
Appropriate use                                       2
15
General safety instructions                              2
16
Warning about misuse                                 2
17
Exclusion of liability                                    2
2
Product description
21
Purpose and use                                      2
22
Ordering code                                        2
23
Special versions                                      2
24
Included in delivery                                    2
25
Technical data                                        2
26
Response time (reaction time)                           3
27
Safety classification                                   3
28
Modes of operation / functions                           3
281 Protection mode with automatic (automatic)                 3
282 Protection mode with restart interlock                      3
283 Test input                                            3
284 Parameter setting                                     3
285 Self-test                                             4
3
Mounting
31
General conditions                                    4
32
Protection field and approach                            4
33
Aligning the sensors                                   4
34
Alignment mode                                      4
35
Safety distance                                       5
351 Minimum distance to reflecting surfaces                    5
36
Interference / Beam coding                              6
37
Dimensions                                          6
38
Mounting material (Not included in delivery!)                6
4
41
42
5
51
52
53
54
55
6
61
62
63
7
71
72
8
81
9
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the
safe operation and disassembly of the safety device The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the device into operation
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine
EN
SLB240
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLB240 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SLB240

  • Page 1: Table Of Contents

    Electrical connection Wiring example SLB240                                7 Connector configuration Receiver, Transmitter & Cable         8...
  • Page 2 Termination male connector ➁ Cable with connector Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: • Range 03 m  150 m productsschmersalcom 2.3 Special versions...
  • Page 3 Operating instructions Safety light barriers SLB240 Detection capability is reduced with moving test body Further 2.8.2 Protection mode with restart interlock information available from technical sales department In the operating mode restart interlock, the safety switching outputs To IEC 61131-2...
  • Page 4 Operating instructions Safety light barriers SLB240 Parameter setting with adapter cable KA-0977 During operation, the system executes a cyclic self-test Safety-relevant • Switch the supply voltage off faults are detected within the reaction time and cause the outputs to be •...
  • Page 5 Operating instructions Safety light barriers SLB240 Activating alignment mode with 5-pole cable connection The safety distance between the safety light barrier and the If through power-up 24V is applied to the restart input via a pushbutton hazardous point must always be respected and observed If...
  • Page 6 3.6 Interference / Beam coding 3.7 Dimensions If there is a risk of a receiver picking up the light signals from other transmitters, each system must be operated with its own beam coding Dimensions of transmitter and receiver SLB240-ER-x-ST ¤ No interference Reciprocal interference!
  • Page 7: Electrical Connection

    15M-BK-2-X-A-1 5-pole * For use in the operating mode Restart Interlock (manual reset) 4. Electrical connection 4.1 Wiring example SLB240 Earth connection Protective mode / Automatic active: Delivery state (Command device button S1 not connected) Restart Interlock (manual reset) active:...
  • Page 8: Connector Configuration Receiver, Transmitter & Cable

    Operating instructions Safety light barriers SLB240 4.2 Connector configuration Receiver, Transmitter & Cable 5.2 Maintenance TRANSMITTER Do not use the AOPD before the next inspection has been Connector completed An incorrect installation can lead to serious and mortal injuries Designation...
  • Page 9: Diagnostic

    8.1 Contact Consultancy / Sales: On the receiver, the indicator is delayed until there is no K.A. Schmersal GmbH & Co. KG change in the ON state or OFF state of the OSSDs for Möddinghofe 30 5 seconds 42279 Wuppertal Germany 6.2 Status display...
  • Page 10: Eu Declaration Of Conformity

    Authorised signature Klaus Schuster Christian Spranger Managing Director Managing Director The currently valid declaration of conformity can be downloaded from the internet at productsschmersalcom K.A. Schmersal GmbH & Co. KG Möddinghofe 30, 42279 Wuppertal Deutschland Telefon: +49 202 6474-0 Telefax:...