schmersal SLC 220 IP 69 K Operating Instructions Manual

schmersal SLC 220 IP 69 K Operating Instructions Manual

Safety light curtain / safety light grid

Advertisement

Quick Links

Operating instructions
Safety light curtain / safety light grid
Operating instructions. . . . . . . . . . . .pages 1 to 14
Translation of the original operating instructions
Vous trouverez la version
FR
actuelle du mode d'emploi dans
votre langue nationale officielle
sur l'Internet,
www.schmersal.net.
U vindt de huidige versie van de
NL
gebruikshandleiding in uw
officiële landstaal op het Inter-
net, www.schmersal.net.
EU公用語で書かれた最新の取扱
JP
説明書は,インターネッ
(www.schmersal.net) からダウ
ンロードできます。
Content
1
1.1
Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2
Target group: authorised qualiied personnel . . . . . . . . . . . . . . . .1
1.3
Explanation of the symbols used. . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4
Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5
General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.6
Warning about misuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7
Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1
Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2
Special versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3
Scope of delivery and accessories . . . . . . . . . . . . . . . . . . . . . . . .2
2.4
Destination and use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.6
Response time (reaction time) . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.7
Safety classiication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.8
Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.8.1 Protective mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.8.2 Restart interlock (manual reset) . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.8.3 Fixed blanking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.8.4 Contactor control EDM (feedback) . . . . . . . . . . . . . . . . . . . . . . . .4
2.8.5 Start interlock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2.8.6 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3
3.1
General conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.2
Protection ield and approach . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.3
Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.4
Safety distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.4.1 Minimum distance to relecting surfaces . . . . . . . . . . . . . . . . . . . .7
3.5
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4
4.1
Wiring example default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.2
(+ possibly accessories cable) . . . . . . . . . . . . . . . . . . . . . . . . . .10
Encontrará el manual de
ES
instrucciones actual en su
idioma oficial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lingua
ufficiale UE) è scaricabile in
Internet all'indirizzo
5
5.1
Check before start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.3
Regular check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.4
Half-yearly inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.5
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6
6.1
LED status information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6.2
Fault diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6.3
Extended diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7
7.1
Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7.2
Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
8
8.1
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
8.2
EC Declaration of conformity. . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version
in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional informa-
tion.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machinery or plant.
EN
SLC 220 IP 69 K
SLG 220 IP 69 K
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLC 220 IP 69 K and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SLC 220 IP 69 K

  • Page 1: Table Of Contents

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K Set-up and maintenance Check before start-up ....... . . 11 Maintenance .
  • Page 2: Www.schmersal.net

    Range 5 m ... 30 m (high range) Further technical information can be found in the Schmersal Only if the information described in this operating instruc- tions manual are realised correctly, the safety function and catalogues or in the online catalogue on the Internet: www.
  • Page 3: Technical Data

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K Connection: screwed cable gland M16 x 1,5 If liquids with aggressive ingredients are used for cleaning, Cable length 5,0 m please check whether the product used is compatible with the material of the sensor (refer to chapter "Technical data").
  • Page 4: Functions

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K 2.8 Functions 2.8.3 Fixed blanking The system consists of a receiver and a transmitter. For the described The SLC 220 can blank stationary parts in the protection field.
  • Page 5: Start Interlock

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K 2.8.5 Start interlock 3. Mounting The start interlock prevents an automatic start of the machine when the 3.1 General conditions supply voltage is switched on. After enabling of the start interlock - by...
  • Page 6: Alignment

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K Correct installation The approach speed is covered with a value of 2000 mm/s Hazardous machine parts can only be reached If value S <= 500 mm after the calculation of the safety distance, then after passing through the protection field.
  • Page 7: Minimum Distance To Relecting Surfaces

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K Safety distance for multi-beam version SLG 220 (beam distance 3.4.1 Minimum distance to reflecting surfaces 300, 400 and 500 mm) During the installation, the effects of reflecting surfaces must be taken into account.
  • Page 8: Dimensions

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K 3.5 Dimensions SLG 220 multi-beam transmitter and receiver All measurements in mm. SLC 220 IP69K default transmitter and receiver Legend A Protection field height...
  • Page 9 Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K Accessories Fixing kit MS-1035...
  • Page 10: Electrical Connection

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K 4. Electrical connection 4.1 Wiring example default Optional function: Use input only for contactor control - activa- tion through NSR-0700 If the function is not activated, do not wire the input.
  • Page 11: Set-Up And Maintenance

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K 5. Set-up and maintenance 5.3 Regular check A regular visual inspection and functional test, including the following 5.1 Check before start-up...
  • Page 12: Diagnostic

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K 6. Diagnostic 6.1 LED status information Transmitter Receiver IR power Restart interlock (manual reset) External test / blanking Signal quality Function...
  • Page 13: Extended Diagnostic

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K 6.3 Extended diagnostic 8. Appendix By means of the optional configuration software and the NSR-0700 8.1 Contact BUS converter, an extended diagnostic can be executed. The software...
  • Page 14: Operating Instructions

    Operating instructions SLC 220 IP 69 K Safety light curtain / safety light grid SLG 220 IP 69 K Appendix 8.2 EC Declaration of conformity EC Declaration of conformity Translation of the original declaration of conformity Safety Control GmbH Am Industriepark 33 84453 Mühldorf / Inn...

This manual is also suitable for:

Slg 220 ip 69 k

Table of Contents