Inhalt
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.3 Set-up instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 Sensor coniguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8.3 Actuator coniguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8.4 Flow diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8.5 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Encontrará el manual de
ES
instrucciones actual en su
idioma oicial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lingua
uficiale UE) è scaricabile in
Internet all'indirizzo www.
schmersal.net.
1 About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the
safe operation and disassembly of the safety-monitoring module.
The operating instructions must be available in a legible condition
and a complete version in the vicinity of the device.

1.2 Target group: authorised qualiied personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the
plant operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical speciications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the proper functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instructions
manual, the country-speciic installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Elan
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is provided
without liability and is subject to technical modiications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of inadequate or improper use or manipulations of the
safety-monitoring module, personal hazards or damage to ma-
chinery or plant components cannot be excluded. The relevant
requirements of the standard EN 1088 must be observed.
EN
SRB 202MSK /
SRB 202MSK/QS
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 202MSK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SRB 202MSK

  • Page 1 Operating instructions SRB 202MSK / Safety-monitoring module SRB 202MSK/QS 1 About this document 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety-monitoring module.
  • Page 2 Operating instructions SRB 202MSK / Safety-monitoring module SRB 202MSK/QS 2.4 Technical data 1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from General data: defective mounting or failure to comply with this operating instructions IEC/EN 60204-1, EN 60947-5-1;...
  • Page 3 X23 L84 X13 LA2 14 X23 L84 X13 LA2 14 All measurements in mm. Device dimensions (H/W/D): 100 x 45 x 121 mm with plugged-in terminals: 120 × 45 × 121 mm Fig. 1: SRB 202MSK Fig. 2: SRB 202MSK/QS...
  • Page 4 The following conditions must be previously checked and met: 1. Correct ixing connection of the SRB 202MSK / SRB 202MSK/QS and connect a muting lamp to the outputs LA1 and LA2 (min. 100 mA, max. 500 mA). 2. Check the integrity of the cable entry and connections •...
  • Page 5 • The control system recognises wire-breakage and earth faults in the monitoring circuit. S22 X13 23 X23 • Only SRB 202MSK/QS: Cross-wire shorts between the monitoring circuits are detected. • Electronic fuse F1: 1.25 A • S = Feedback circuit SRB 202MSK L84: …….
  • Page 6 SRB 202MSK SRB 202MS… L84: ……. A L84: ……. A Fig. 10: SRB 202MSK a) Muting sensors, Fig. 12: SRB 202MSK or SRB 202MSK/QS b) Bridge; a) Muting sensors, c) AOPD (semi-conductor outputs); b) Bridge; d) Elan safety relay c) AOPD (relay outputs);...
  • Page 7 Fig. 17 Dual-channel muting circuit (Fig. 14) • Wire breakage and earth leakage in the control circuits are detected. • The SRB 202MSK/QS detects cross-wire shorts between the muting sensors. • With external reset button • The reset button is integrated in the feedback circuit in series.
  • Page 8 Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. Elan Schaltelemente GmbH & Co. KG Im Ostpark 2, D - 35435 Wettenberg Postfach 1109, D - 35429 Wettenberg Telefon:...