Download Print this page
schmersal SLC 420 IP 69 K Operating Instructions Manual
schmersal SLC 420 IP 69 K Operating Instructions Manual

schmersal SLC 420 IP 69 K Operating Instructions Manual

Safety light curtain

Advertisement

Quick Links

Operating instructions
Safety light curtain
Operating instructions           pages 1 to 16
EN
Translation of the original operating instructions
Content
1
About this document
11
Function                                            1
12
Target group: authorised qualified personnel                1
13
Explanation of the symbols used                         1
14
Appropriate use                                       1
15
General safety instructions                              2
16
Warning about misuse                                 2
17
Exclusion of liability                                    2
2
Product description
21
Ordering code                                        2
22
Special versions                                      2
23
Scope of delivery and accessories                        2
24
Destination and use                                   3
25
Technical data                                        3
26
Response time (reaction time)                           4
27
Safety classification                                   4
28
Functions                                           4
281 Protective mode                                      4
282 Restart interlock (manual reset)                          4
283 Fixed blanking                                        5
284 Variable blanking                                      5
285 Contactor control (EDM)                                6
286 Start interlock                                        6
29
Testing                                              6
210 Beam coding                                         6
3
Mounting
31
General conditions                                    6
32
Protection field and approach                            6
33
Alignment                                           7
34
Safety distance                                       7
341 Minimum distance to reflecting surfaces                    8
35
Dimensions                                          9
36
Mounting kit MS-1038                                  9
4
Electrical connection
41
Wiring example                                      10
42
Activation of the contactor control (EDM) without software     11
43
Connector configuration Receiver & Emitter
(possibly accessories cable)                             11
5
Set-up and maintenance
51
Check before start-up                                 12
52
Maintenance                                        12
53
Regular check                                       12
54
Half-yearly inspection                                 12
55
Cleaning                                           12
6
Diagnostic
61
LED status information                                12
62
Fault diagnostic                                      13
63
Extended diagnostic                                  13
7
Disassembly and disposal
71
Disassembly                                        14
72
Disposal                                           14
8
Appendix
81
Contact                                            14
82
EC Declaration of conformity                           15
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear The operating
instructions must be available in a legible condition and a complete ver-
sion in the vicinity of the device
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only
Please make sure that you have read and understood these operat-
ing instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional informa-
tion
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machinery or plant
EN
SLC 420 IP 69 K
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SLC 420 IP 69 K and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SLC 420 IP 69 K

  • Page 1 Operating instructions Safety light curtain SLC 420 IP 69 K Electrical connection Wiring example                                      10 Activation of the contactor control (EDM) without software     11 Connector configuration Receiver &...
  • Page 2 Protection field heights in mm available ➀ Further technical information can be found in the Schmersal lengths: 0170, 0250, 0330, 0410, 0490, catalogues or in the online catalogue on the Internet: 0570, 0650, 0730, 0810, 0890, 0970, 1050,...
  • Page 3 Operating instructions Safety light curtain SLC 420 IP 69 K MSD4 Vibration damper Admissible conduction resistance Kit consisting of: 8 vibration dampers 15 x 20 mm, 8 M5 cylinder head between OSSD and load: 2,5 Ω screws with hexagon socket, 8 spring washers Supply cable: 1 Ω...
  • Page 4 Operating instructions Safety light curtain SLC 420 IP 69 K 2.6 Response time (reaction time) The system has the following features: The response time depends on the hight of the protected field, the • Protective mode (automatic start after release of the protected field) resolution, the number of light beams and the beam coding •...
  • Page 5 Operating instructions Safety light curtain SLC 420 IP 69 K 2.8.3 Fixed blanking This function allows for an interruption of the protection height without The SLC 420 can blank stationary parts in the protection field the outputs being disabled in case of material movement in the protec-...
  • Page 6 Operating instructions Safety light curtain SLC 420 IP 69 K 2.8.5 Contactor control (EDM) • The beam coding increases the safety and avoids mutual interference The contactor control monitors the controlled switching elements of adjacent systems (auxiliary contacts of the contactors) of both outputs This monitoring •...
  • Page 7 Operating instructions Safety light curtain SLC 420 IP 69 K Correct installation Safety light curtain SLC 420 The safety distance for resolutions 14 mm up to 40 mm is calculated by Hazardous machine parts can only be reached means of the following formula:...
  • Page 8 Operating instructions Safety light curtain SLC 420 IP 69 K Safety distance to the hazardous area Safety distance a a [mm] Safety distance (S) Limit of the hazardous point 1000 Tool - upper part Signal to stop the hazardous movement...
  • Page 9 Operating instructions Safety light curtain SLC 420 IP 69 K 3.5 Dimensions Accessories All measurements in mm 3.6 Mounting kit MS-1038 ¤5,5 Legend Protection field height Sensor length Mounting dimension total length Type SLC 420-E/R0170-xx-69-RFB SLC 420-E/R0250-xx-69-RFB SLC 420-E/R0330-xx-69-RFB SLC 420-E/R0410-xx-69-RFB...
  • Page 10 Operating instructions Safety light curtain SLC 420 IP 69 K 4. Electrical connection 4.1 Wiring example Kn 1 Kn 2 Earth connection Erdung Restart interlock (manual reset) (bridge 1) By bridging DIAG IN (pin 5) and DIAG OUT (pin 6), the restart interlock...
  • Page 11 Operating instructions Safety light curtain SLC 420 IP 69 K 4.2 Activation of the contactor control (EDM) without software 4.3 Connector configuration Receiver & Emitter The contactor control can be activated without PC software as of (possibly accessories cable) firmware version 123 in diagnostic mode by means of cable bridges...
  • Page 12 Operating instructions Safety light curtain SLC 420 IP 69 K 5.1 Check before start-up 5.3 Regular check Prior to start-up, the following items must be checked by the responsi- A regular visual inspection and functional test, including the following ble person...
  • Page 13 Operating instructions Safety light curtain SLC 420 IP 69 K Receiver Status LED Description OSSD ON Protection field clear flashing Diagnostic mode active OSSD OFF Protection field interrupted, system or configuration error flashing Diagnostic mode active, error output refer to Fault diagnostic table...
  • Page 14 Operating instructions Safety light curtain SLC 420 IP 69 K 7. Disassembly and disposal 8. Appendix 7.1 Disassembly 8.1 Contact The safety switchgear must be disassembled in a de-energised condi- Consultancy / Sales: tion only KA Schmersal GmbH Industrielle Sicherheitsschaltsysteme 7.2 Disposal...
  • Page 15 Operating instructions Safety light curtain SLC 420 IP 69 K Appendix 8.2 EC Declaration of conformity EC Declaration of conformity Translation of the original declaration of conformity Safety Control GmbH Am Industriepark 33 84453 Mühldorf / Inn Germany We hereby certify that the hereafter described safety components both in its basic design and con-...
  • Page 16 Safety Control GmbH Am Industriepark 33 D-84453 Mühldorf / Inn Telefon +49 - (0)86 31 - 187 - 9 60 Telefax +49 - (0)86 31 - 187 - 9 61 E-Mail: info@safetycontrolcom...