IMPROPER INSTALLATION
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty. The manufacturer will not be held responsible
for damage caused by the malfunction of a stove due to
improper venting or installation.

FLOOR PROTECTION

This heater must have a non-combustible floor protector
(UL1618 ember protection) installed beneath it if the floor
is of combustible material. The floor protector should
be listed to UL 1618 or equivalent to type 1 ember floor
protection. The floor protection must extend 6" to the
front, 6" on each side and 1" to the rear of the appliance
See diagram for further information
A
Back to Stove
B
Side to Stove
C
Front to Stove
D
Back to Flue
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please
adhere to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be done
by means approved by a regulatory authority.
© 2022 United States Stove Company
1"
26mm
6"
153 mm
6"
153 mm
2"
51 mm
E
Side Wall to Stove
F
Side Wall to PL Vent Pipe
G
Back Wall to Stove
H
Back Wall to PL Vent Pipe
J
Ceiling to Floor
K
Ceiling to Stove
L
Wall to Stove
M
Side Wall to PL Vent Pipe
N
Wall to PL Vent Pipe
OUTSIDE AIR SUPPLY
IN A MOBILE HOME)
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home.
You can purchase the 69FAK through your heater dealer.