This E110-series tutorial is meant as a step-by-step guidance on how to use and
set the automatic unit conversion. This tutorial is an addendum to the installation
manual that came with the E-series.
This E110-series tutorial assumes that the E-series is in a safe area.
E-series - Explosion proof indicators for hazardous areas.
FW_E110_AutoUnitConv_002_EN
E-SERIES
Flow rate indicator / Totalizer
E110-SERIES TUTORIAL
AUTOMATIC UNIT CONVERSION
More info: www.fluidwell.com/eseries
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Fluidwell E Series

  • Page 1 This tutorial is an addendum to the installation manual that came with the E-series. This E110-series tutorial assumes that the E-series is in a safe area. E-series - Explosion proof indicators for hazardous areas. More info: www.fluidwell.com/eseries FW_E110_AutoUnitConv_002_EN Page 1...
  • Page 2 Nothing from this E110-series tutorial may be reproduced, or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording or any information storage or retrieval system without prior written approval by Fluidwell BV. Trademarks All trademarks used in this E110-series tutorial are the property of their respective owners.
  • Page 3: Table Of Contents

    E110-SERIES TUTORIAL AUTOMATIC UNIT CONVERSION Table of content DESCRIPTION OF THE AUTOMATIC UNIT CONVERSION ..........4 The relation between the K-Factor and the automatic unit conversion ........4 The relation between the K-Factor and the measurement unit set by hand ......4 HOW TO SETUP THE AUTOMATIC UNIT CONVERSION ...........
  • Page 4: Description Of The Automatic Unit Conversion

    AUTOMATIC UNIT CONVERSION E110-SERIES TUTORIAL 1 Description of the automatic unit conversion The automatic unit conversion is a feature that helps you to avoid the different K-Factor calculations for the (accumulated) total and the flowrate. With the automatic unit conversion, you only need the test/calibration certificate that came with your flowmeter.
  • Page 5: How To Setup The Automatic Unit Conversion

    E110-SERIES TUTORIAL AUTOMATIC UNIT CONVERSION 2 How to setup the automatic unit conversion This chapter explains the procedure how to setup the automatic unit conversion. 2.1 How to set the K-Factor (units) for the flowmeter For easy access the procedure gives the action (what to do), the result (how the E-series will respond) and a notice to give additional information to make the procedure more easy to do.
  • Page 6 AUTOMATIC UNIT CONVERSION E110-SERIES TUTORIAL ACTION RESULT OTICE  The m 10. Press the ▲ button to Read the unit from the flowmeter selection shows make the required certificate and select the same (the flowmeter is selection. measurement unit in this menu. calibrated for m /hr).
  • Page 7: The Automatic Unit Conversion - Hand Mode

    E110-SERIES TUTORIAL AUTOMATIC UNIT CONVERSION 2.1.2 The automatic unit conversion - HAND mode This procedure gives the information how to setup the HAND mode. The HAND mode is selected when the required measurement unit is not supported by the automatic unit conversion.
  • Page 8 AUTOMATIC UNIT CONVERSION E110-SERIES TUTORIAL ACTION RESULT OTICE  The selection US GAL Press the ▲ button to For the explanation, make the required shows. the measurement unit for the selection. (accumulated) total is set to US GAL.  The PROG indicator Press the PROG button The Flowmeter (K-factor) unit m momentarily.
  • Page 9: The (Accumulated) Total - Hand Mode

    E110-SERIES TUTORIAL AUTOMATIC UNIT CONVERSION 2.2.2 The (accumulated) total - HAND mode This procedure gives the information how to setup the HAND mode. The HAND mode is selected when the required measurement unit is not supported by the automatic unit conversion.
  • Page 10: Set The Reading For The Flow Rate

    AUTOMATIC UNIT CONVERSION E110-SERIES TUTORIAL ACTION RESULT OTICE  The PROG indicator goes 13. Press the PROG button momentarily. off.  The selection is confirmed. 14. Press the ▲ button until  The K-Factor decimals the K-F DECS menu menu shows. shows.
  • Page 11 E110-SERIES TUTORIAL AUTOMATIC UNIT CONVERSION ACTION RESULT OTICE  The UNIT menu shows. Press the ▲ button until the UNIT menu shows.  The PROG indicator Press the PROG button Now you can set the measurement momentarily. unit for display purpose only.. comes on.
  • Page 12: The Flow Rate - Hand Mode

    AUTOMATIC UNIT CONVERSION E110-SERIES TUTORIAL ACTION RESULT OTICE  The selection PLS 10 16. Press the ▲ button to For the explanation, make the required shows. the flow rate calculation is set to selection. PLS 10 for 10 pulses per measurement unit.
  • Page 13 E110-SERIES TUTORIAL AUTOMATIC UNIT CONVERSION ACTION RESULT OTICE  The PROG indicator goes Press the PROG button momentarily. off.  The selection is confirmed. Press the ▲ button until  The TIME menu shows. the TIME menu shows.  The PROG indicator Press the PROG button Now you can set the time unit for momentarily.
  • Page 14 AUTOMATIC UNIT CONVERSION E110-SERIES TUTORIAL ACTION RESULT OTICE  The CALCULATE menu 22. Press the ▲ button until The flow rate is calculated by the CALCULATE menu measuring the time between a shows. shows. number of pulses. The more pulses, the more accurate the flow rate will be but also the response time will decrease.
  • Page 15 E110-SERIES TUTORIAL AUTOMATIC UNIT CONVERSION NOTES …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. …………………………………………………………………………………………………………. ………………………………………………………………………………………………………….
  • Page 16 AUTOMATIC UNIT CONVERSION E110-SERIES TUTORIAL Fluidwell BV PO box 6 Voltaweg 23 Website: www.fluidwell.com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative: www.fluidwell.com/representatives Page 16 FW_E110_AutoUnitConv_002_EN The Netherlands The Netherlands...

This manual is also suitable for:

E110 series

Table of Contents