JB Systems CAM-SPOT 50TW Operation Manual page 7

Table of Contents

Advertisement

ENGLISH
DMX Addr
Used to set the desired DMX-address.
• Press the [MENU] button or [UP]/[DOWN] buttons until the desired function is showing on the display.
• Press the [ENTER] button: the DMX value can now be changed
• Use UP/DOWN buttons to select the desired DMX512 address. The last occupied DMX-address is also
shown: this makes it easier to set the address of the next unit in the chain.
• Once the correct address shows on the display, press the [ENTER] button to save it.
DMX Chan
Used to set the desired channel mode.
• Press the [MENU] button or [UP]/[DOWN] buttons until the desired function is showing on the display.
• Press the [ENTER] button: the values can be changed
• Use [UP]/[DOWN] buttons to select the desired mode:
• [2.1CH]: CW + WW.
• [2.2CH]: Dimmer + CCT.
• [3CH]: CW + WW+ Dimmer.
• [4CH]: CW + WW+ Dimmer + Strobe.
• Once the correct option shows on the display, press the [ENTER] button to save it.
Mas/Slav
Used to set the projector as slave in a master/slave setup.
• Press the [MENU] button or [UP]/[DOWN] buttons until the desired function is showing on the display.
• Press the [ENTER] button: The values can be changed.
Strobe
Used to set the Strobe while used in manual mode.
• Press the [MENU] button or [UP]/[DOWN] buttons until the desired function is showing on the display.
• Press the [ENTER] button: the values can be changed
• Use [UP]/[DOWN] buttons to select the desired level for the master dimmer. (please note that the last
selected static color will be used to set the value)
• Once you have the desired level, press the [ENTER] button to save it.
DMX Fail
Used to set the desired DMX loss setting
• Press the [MENU] button or [UP]/[DOWN] buttons until the desired function is showing on the display.
• [Hold]
• [Manual]
• [Black-Out]
• Once the correct option shows on the display, press the [ENTER] button to save it.
Note: as soon as the input detects a DMX-signal, Hold, Manual or Black-Out mode will be cancelled.
Temp
Used to monitor the internal temperature of the fixture.
• Press the [MENU] button or [UP]/[DOWN] buttons until the desired function is showing on the display.
• Press the [ENTER] button: Display the internal temperature.
DimMode
Used to select the reaction time of the projector.
• Press the [MENU] button or UP/DOWN buttons until the desired function is showing on the display.
• Press the [ENTER] button: the values can be changed
• Use UP/DOWN buttons to select the desired mode:
• [Off]
• [Dim1..4]
• Once the correct option shows on the display, press the [ENTER] button to save it.
Factory
This is your emergency exit if you really messed up the settings: just return to factory settings.
Also 2 user settings can be saved/loaded.
• Press the [MENU] button or [UP]/[DOWN] buttons until the desired function is showing on the display.
• Press the ENTER button: the values can be changed
JB SYSTEMS
®
Projector keeps the last valid output before DMX loss
Projector goes to manual mode when DMX is lost
Projector output turns dark when DMX is lost
The projector follows the instructions instantly, no delay.
The projector imitates the behavior of a halogen lamp (slower reaction time).
5/8
OPERATION MANUAL
CAM-SPOT 50TW

Advertisement

Table of Contents
loading