en | Maintenance
17

Maintenance

Regular maintenance of your MIC camera will preserve the MIC, especially the surface finish,
for an extended period.
Cleaning – Remove power from the device before cleaning. Generally, using a dry cloth for
cleaning is sufficient, but a moist, fluff-free cloth may also be used. Do not use liquid cleaners
or aerosol cleaners.
In corrosive environments, you should clean the camera surface periodically with fresh water.
4
Use a flow rate of 150-145 liter/minute. Hold the nozzle a minimum distance of 1 m from the
camera.
4
Note: Do not use water pressure greater than 96.5 kPa (14 psi) to wash the unit.
No User-serviceable Parts
Except for the external wiper blade, the device contains no user-serviceable parts. Contact
your local Bosch service center for device maintenance and repair. In the event of failure, the
device should be removed from site for repair.
On-Site Inspection
It is recommended that the device be inspected on-site every six months to check mounting
bolts for tightness, security, and any signs of physical damage. Inspection of this device shall
only be carried out by suitably-trained personnel in accordance with the applicable code of
practice (for example, EN 60097-17).
Information about cameras with illuminators
The text in this section applies only to cameras which have the optional illuminator accessory.
When servicing the device, disconnect power to the device to avoid possible exposure to the
eyes. If disconnecting power to the device is not possible, use appropriate shielding to block
the LED arrays or wear appropriate eye protection.
Illuminator removal
If you must remove the illuminator because it is damaged or has failed, follow these steps:
1.
2.
Note: If you do not have an access plug, do not remove the illuminator until you request and
receive a new access plug from Bosch.
2022-09 | 2.1 |
Wash the camera thoroughly with fresh water:
Regularly (1-2 times per quarter, or more frequently if possible)
Immediately after an event such as a sea storm that could introduce a layer salt on the
camera's surface
In certain use cases, it might help to use a solution of hydrophobic liquid to prevent long-
term buildup of salt layers on the camera's surface.
Remove the three (3) M4 Hex screws.
Install the access plug (which may be stored in an access hole of the MIC-DCA or the wall
mount accessory; if not, see the note below).