Wiring Connections

Power Connector

A 12 VDC power supply is provided with the DTP2 R 212. Follow these instructions to wire
the 2‑pole captive screw connector to your power supply:
CAUTION: The DC output cables must be kept separate from each other while the
ATTENTION : Les câbles de sortie CC doivent être séparés les uns des autres tant que
ATTENTION:
1.
2.
3.
4.
5.
Reset button (see
figure 3
press and hold the recessed reset button:
Press and hold for 3 seconds to reset back to factory default. IP settings are
retained.
Press and hold for 10 seconds to reset back to factory default. IP settings are reset
to default.
Press and hold while powering the unit on enables the unit to revert to factory
default firmware version and factory default setting.
NOTE: The receiver can also be reset to factory settings using SIS commands (see
Reset
on page 50) or PCS (see
power supply is plugged in. Remove power before wiring.
la source d'alimentation est branchée. Coupez l'alimentation avant d'effectuer tout
raccordement.
Do not connect power to the DTP2 R 212 until you have read the ATTENTION
notifications on the next page.
Ne branchez pas l'alimentation au DTP2 R 212 avant d'avoir lu les mises en garde
« ATTENTION » en page suivante.
Cut the DC output cord to the length needed.
Strip the jacket to expose 3/16 inch (5 mm) of the conductors (see figure 6).
Slide the leads into the supplied 2‑pole captive screw connector and secure them,
using a small screwdriver.
A
Smooth
Ridges
SECTION A–A
A
Figure 6.
Wiring the Power Connector
To verify the power cord polarity before connecting the plug, connect the power supply
with no load and check the output with a voltmeter.
Use the supplied tie wrap to strap the power cord to the extended tail of the connector.
on page 7) — With a tweeker or other pointed tool,
Device Menu
on page 31).
3/16"
(5 mm) Max.
DTP2 R 212 Series • Installation
POWER
12V