Toshiba RAV-HM561UTP Series Service Manual page 42

Split type indoor unit 4-way cassette type
Table of Contents

Advertisement

No.
Item
23
8°C heating/
1) This functional is intended for the cold latitudes and performs
Frost protective
operation
2) This function is valid only for combination with the outdoor
3) Using the indoor DN code [D1] (1 bit), Valid/Invalid of this
4) This operation is the heating operation which sets 8°C as
5) This function starts operation by pushing temperature
6) To stop/release this operation, select and execute one from
7) As the setup temperature is 8°C and the human heating is not
8) The settings of the air direction and air volume are
9) The indoor fan stops to protect the compressor for
Occupancy
1) During the Occupancy sensor operation (DN code: [B5]
24
sensor
2) The Occupancy sensor operation can change by [DN code :
3) The operation at absent time can be changed by [DN code :
4) If the operation at absent time stops during group operation,
Outline of specifications
objective heating operation (8°C heating operation).
units (Super Digital Inverter (SDI) 4-series outdoor units).
function is set up at the customer's side.
∗ The setup by DN code is Invalid [0]/Valid [1] and Invalid [0]
has been set at the shipment.
the setup temperature of the target.
button
during heating operation; besides by pushing
button for 4 seconds or more after temperature
reached the minimum set temperature.
the following operations.
Push
button: Heating operation (18°C setting)
continues.
Push [START/STOP] button: Air conditioner stops.
(Heating 18°C operation at the next start)
MODE
Push
: Other operation mode is selected and the
operation continues.
targeted, the cold air discharge preventive control (Item 7) is
made invalid to suppress the intermittent operation.
changeable during this operation.
2 minutes after start of heating operation (Thermo-ON) by
this function.
[0001] and [B6] [0002 to 0005]), when there is no people in
the Occupancy sensor range, it is automatically switched to
the operation for the absence.
B6] as follows, and operates according to the operation at
absent time, if time or absence of the setting contents
continues. However time counting starts after the room
temperature is stabilized. (after for 30 minutes operation)
DN [B6]
Data
0000
0001 to 0005
B7].
DN [B7]
Data
0000
0001
or absence is fixed in each system, the operation starts
circular operation once, and then the operation stops when
absence was determined on all group.
* DN [06] and DN [B7] can be set on the "Occupancy sensor"
menu of the wired remote controller RBC - AMSU5∗.
Setting contents
Invalid
30 minutes to 150 minutes
(30 minutes each)
Operation at absent time
Circulator
Operation stop
- 42 -
Remarks
In a group connection,
if there is even one
combination with other
unit, "This function is not
provided." is displayed.
The setup temperature
jumps from [18] to [8].
The Occupancy sensor
can be set up by wired
remote controller
RBC-AMSU5∗