Summary of Contents for Toshiba RAV-HM561UTP-E

  • Page 1 AIR CONDITIONER (SPLIT TYPE) Owner’s Manual Indoor Unit For commercial use Model name: 4-way Cassette Type RAV-HM561UTP-E RAV-HM801UTP-E RAV-HM901UTP-E RAV-HM1101UTP-E RAV-HM1401UTP-E RAV-HM1601UTP-E English...
  • Page 2: Table Of Contents

    – 1 – Original instruction Contents ADOPTION OF R32 REFRIGERANT Precautions for safety ............3 This Air Conditioner has adopted a refrigerant HFC (R32) which does not destroy the ozone layer.
  • Page 3 • The qualified installer is a person who installs, maintains, relocates and removes the air conditioners made by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and remove the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such...
  • Page 4: Precautions For Safety

    – 3 – Precautions for safety Warning indications on the air conditioner unit The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual. Warning indication Description WARNING WARNING WARNING ELECTRICAL SHOCK HAZARD General ELECTRICAL SHOCK HAZARD Disconnect all remote...
  • Page 5 • Before stacking the packing cartons for storage or Operation transportation, heed the precautions written on the packing • Before opening the intake grille of the indoor unit or service cartons. Failure to heed the precautions may cause the stack to panel of the outdoor unit, set the circuit breaker to the OFF collapse.
  • Page 6 – 5 – • When the air conditioner is operated with a combustion • If the fan grille is damaged, do not approach the outdoor unit appliance in the same place, ventilate the room sufficiently. but set the circuit breaker to the OFF position, and contact Poor ventilation causes oxygen shortage.
  • Page 7 • Do not leave flammable sprays or other flammable materials CAUTION near the air conditioner, and do not spray flammable aerosol To disconnect the appliance from the mains supply. directly to the air conditioner. They may catch fire. • This appliance must be connected to the mains by means of a •...
  • Page 8: Part Names

    – 7 – Part names Information on the transportation, handling and storage of the carton Indoor unit Knob Earth screw Examples of indication on the carton Knob to open / close Provided in the electrical Symbol Description Symbol Description control box. the suction port.
  • Page 9: Wired Remote Controller

    Wired remote controller Normal Operation Wind Fan speed Operation mode direction Remote controller model name: RBC-ASCU1* 3.1 Component Names and Functions When operating the button, the LCD backlight will be lightened for 15 seconds. ■ Indication icon ■ Button All the icons shown on the display are for illustrative purposes only. Cooling only model do not show heating-related icons.
  • Page 10 – 9 – ■ Run operation Fan speed indication icon Pre-heat indicator Displayed when the heating mode is energized • Indicate the selected fan speed. or defrost cycle is initiated. While this indication is displayed, the indoor fan Auto stops or operate in fan mode. Auto Low + Med.
  • Page 11: Timer Operation

    For fan Temperature selection Timer operation The louver can be adjusted to six steps. Press the set button to adjust the temperature. Select a wind direction. • Temperature setting range is from 18.0°C to 4.1 Timer off Operation 29.0°C • The sensitivity of temperature adjustment is Timer off: When reaching the setting time, the indoor unit stops running.
  • Page 12: Self Clean Mode

    – 11 – Self clean mode Maintenance This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling WARNING / dry / AUTO (cooling) mode to keep the indoor unit clean. The self clean time varies with the cooling / dry / Auto (cooling) operation time as follows.
  • Page 13: Troubleshooting

    Check periodically • If the unit is used for a long time, parts may deteriorate and cause malfunction or bad drainage of dehumidified water Troubleshooting depending on the heat, humidity, or dust. • In addition to the usual maintenance, it is recommended that you have the unit checked and maintained by the dealer where Check the points described below before requesting repair.
  • Page 14: Operations And Performance

    – 13 – ■ Confi rmation and check Operations and performance If there is something unusual even after checking the above, stop running the unit, turn off the circuit breaker, and inform the dealer where you purchased the product of the product number and symptom. Do not attempt to repair Check before running Protective device the unit by yourself as doing so is dangerous.
  • Page 15: Installation

    Do not install the air conditioner near a high frequency appliance (sewing machine or massager for business use, etc.), • RAV-HM561UTP-E otherwise the air conditioner may malfunction. RAV-HM801UTP-E Do not install the air conditioner in locations where iron or other metal dust is present.
  • Page 16 – 15 – Declaration of Conformity Declaration of Conformity Manufacturer: Toshiba Carrier (Thailand) Co., Ltd. Manufacturer: Toshiba Carrier (Thailand) Co., Ltd. 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi,...
  • Page 17 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand 1115350295...