Summary of Contents for ThermoFisher Scientific Microliter 48 x 2 sealed
Page 1
Thermo Scientific Microliter 48 x 2 sealed Instruction Manual 50120031-e • 05 / 2020 Visit us online to register your warranty: thermofisher.com/labwarranty...
Page 2
WEEE Conformity This product is subject to the regulations of the EU Waste Electrical & Electronic Equipment (WEEE) Directive 2012/19/EU. It is marked by the following symbol:...
If any parts are missing, please contact the nearest Thermo Fisher Scientific representative. Precautions In order to ensure safe operation of the Microliter 48 x 2 sealed, the following general safety regulations must be followed: • Do not remove the magnet at the rotor bottom.
Page 8
WARNING means that injuries or material damage or contamination could occur. This symbol refers to biological hazards. Observe the information contained in the instruction manual to keep yourself and your environment safe. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 10
Accel. / braking time [s] 45 / 45 Sample heating at n [°C] referred to ambient temperature of 23 °C, running time 120 minutes Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 11
RCF value at n 25,314 max. / min. radius [cm] 9.8 / 5.9 Pitch angle [°] Accel. / braking time [s] 45 / 45 aerosol-tight permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Page 12
Accel. / braking time [s] 45 / 45 Sample heating at n [°C] referred to ambient temperature of 23 °C, running time 120 minutes Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 13
Maximum RCF value at n 25,314 Max. / min. radius [cm] 9.8 / 5.9 Pitch angle [°] Accel. / braking time [s] 45 / 45 Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Page 14
Accel. / braking time [s] 45 / 45 Sample heating at n [°C] referred to ambient temperature of 23 °C, running time 120 minutes Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 15
Maximum RCF value at n 25,314 Max. / min. radius [cm] 9.8 / 5.9 Pitch angle [°] Accel. / braking time [s] 45 / 45 Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Page 16
Accel. / braking time [s] 45 / 45 Sample heating at n [°C] referred to ambient temperature of 23 °C, running time 120 minutes Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 17
Maximum RCF value at n 25,314 Max. / min. radius [cm] 9.8 / 5.9 Pitch angle [°] Accel. / braking time [s] 45 / 45 Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Page 18
Accel. / braking time [s] 45 / 40 Sample heating at n [°C] referred to ambient temperature of 23 °C, running time 120 minutes Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK 1-10 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 19
25,314 Max. / min. radius [cm] 9.8 / 5.9 Pitch angle [°] Accel. / braking time [s] 45 / 45 Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK Thermo Scientific 75003602 Microliter 48 x 2 sealed 1-11...
Page 20
9.8 / 5.9 9.8 / 5.9 Pitch angle [°] Accel. / braking time [s] 45 / 45 45 / 45 Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK 1-12 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 21
25,314 Max. / min. radius [cm] 9.8 / 5.9 Pitch angle [°] Accel. / braking time [s] 45 / 45 Aerosol-tight Permissible temperature range autoclavable °C Tested by HPA, Porton-down, UK Thermo Scientific 75003602 Microliter 48 x 2 sealed 1-13...
AutoLock is defective and you are not permitted to operate the rotor. Check for any damage to the rotor, damaged rotors must not be used. Keep the hub area clear of objects. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
CAUTION Rotors supplied with a lid for aerosol-tight applications come with a mandril, ™ which belongs to the AutoLock . Be sure not to place the lid onto this mandril to prevent it from being damaged. Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Page 28
™ AutoLock Aerosol-tight rotors ™ Figure 3-3. AutoLock -lid for aerosol-tight rotors ™ WARNING Mind the AutoLock -mandril inside the lid. Do not touch. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
B-1. 5. Make sure the tubes or bottles do not touch the lid. Proper Loading To ensure safe operation of the centrifuge, the rotor must be evenly loaded at all times. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
There are two options available for centrifuging samples whose weight, including adapter, exceeds the maximum permissible load: • Reduce the fill level. • Reduce the speed. Use the table or the formula: Actual Load (g/cavity) 15200 14493 13876 13331 Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Service life examples Usage profile Maximum service life at 30,000 cycles frequent use 7 years 20 runs / day 220 days / year 75003602 Microliter 48 x 2 sealed Thermo Scientific...
This releases the carbonic acid gas, which is bound in the water, resulting in excess pressure. Do not apply pressure to the lid when doing so. Leaks can be detected by escaping water or the sound of escaping gas. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 35
Damaged seals are to be replaced immediately. When loading the rotor, ensure that the rotor lid closes securely. Damaged or clouded rotor covers are to be replaced immediately. Thermo Scientific 75003602 Microliter 48 x 2 sealed...
• Store the aluminum parts at room temperature or in a cold-storage room with the cavities pointing down. CAUTION Before using any cleaning or decontamination methods except those recommended by the manufacturer, users should check with the manufacturer that the proposed method will not damage the equipment. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
CAUTION Before using any cleaning or decontamination methods except those recommended by the manufacturer, users should check with the manufacturer that the proposed method will not damage the equipment. Observe the safety precautions and handling instructions for the cleaning agents used. Thermo Scientific 75003602 Microliter 48 x 2 sealed...
For general radioactive decontamination, use a solution of equal parts of 70 % ethanol, 10 % SDS and water. Disinfect the rotor and accessories as follows: 1. Open the centrifuge. 2. Turn off the centrifuge. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Note No chemical additives are permitted in the steam. CAUTION Never exceed the permitted temperature and duration when autoclaving. If the rotor shows signs of corrosion or wear, it must be replaced. Thermo Scientific 75003602 Microliter 48 x 2 sealed...
• the lid lock and the safety system; • the rotor; • the fixation of the rotor and the drive shaft. Thermo Fisher Scientific offers inspection and service contracts for this work. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
M S M - Benzyl Alcohol Boric Acid U S S M S S U S S S S S S S S S U S S S S S S S S S S Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Page 50
S S S U S U S S S U ® Ficoll-Hypaque M S S - S S S - S S S S - S S - S S S S S S S M S S S 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 51
S S S U S S M S S S S S U S U M S S S S S S S M S M U Methylene Chloride U U U U M S S U S U U S U U U U U M U U U S S M U S U Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Page 52
S S S S S S S S S S S S S S S S S S S Picric Acid S S U - S M S S S M S U S S S U S S S S U S U M S M S 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 53
Citric Acid (10 %) M S S M S S M S S S S S S S S S M S S S S S S S S S S Polyethyleneterephthalate Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Page 54
Chemical resistance data is included only as a guide to product use. Because, no organized chemical resistance data exists for materials under the stress of centrifugation, when in doubt we recommend pretesting sample lots. 75003602 Microliter 48 x 2 sealed Thermo Scientific...
Page 55
Scope of Supply ..........v Cycle Counter ..........4-4 Service .............6-5 Decontamination ..........6-4 Disinfection ............ 6-2 Fill Level ............5-2 Improper Loading ........... 4-3 Intervals ............6-2 Maintenance ........... 6-1 Maximum Loading ......... 4-3 Thermo Scientific 75003602 Microliter 48 x 2 sealed...
Need help?
Do you have a question about the Microliter 48 x 2 sealed and is the answer not in the manual?
Questions and answers