Modbus - tcp / jbus serial link
Hide thumbs Also See for GREEN POWER 2.0:

Advertisement

green power 2.0
Delphys BC
and
M o d b u s - T C P / J b u s s e r i a l l i n k
Installation and operating manual
GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GREEN POWER 2.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for socomec GREEN POWER 2.0

  • Page 1 2.0 Delphys BC M o d b u s - T C P / J b u s s e r i a l l i n k Installation and operating manual...
  • Page 2 Index 1. Foreword 2. SaFety requirement 2. 1. sing conditions 2. 2. dELPHYs g rEEn owEr PErating EfErEncE 3. environment 3. 1. EcYcLing of ELEctricaL ProdUcts and EqUiPmEnt 4. introduction 4. 1. EnEraL PUrPosE 4. 2. odbUs ProtocoL 4. 3. ata dEcoding 5.
  • Page 3 INDEX 9. modBuS in modular Parallel SyStem conFiGuration 9. 1. EmindEr 9. 2. odbUs tabLE in modULar ParaLLEL sYstEm 9. 3. dEntification 9. 4. & H oUrs 9. 5. onfigUration 9. 6. rELiminarY Emarks 9. 7. tatUs 9. 8. Larms 9.
  • Page 4 CAUTION : “This is a product for restricted sales distribution to informed partners. Installation restrictions or addi- tional measures may be needed to prevent disturbances”. SOCOMEC reserves the right to modify their specifications at any time as far as this contributes to technical progress.
  • Page 5 4. IntRoductIon 4. 1. g EnEraL PUrPosE This document provides required information of the MODBUS protocol serial link or Ethernet network. Before connecting a supervision equipment or BMS system (Building management system) to the UPS, it is neces- sary to install and set up the serial interface or network configurations in the case of a network connection.. 4.
  • Page 6 5. InStaLLatIon of modBuS Rtu caRd 5. 1. ‘c ’ Lots LocaLisation The « Com-Slots » integrates all communication interfaces and it is located on the right side. Please, see on the manual of the concerned UPS to see the correct localisation of the «com slot 2» 5.
  • Page 7 nstallatIon nsIde 5. 4. c onnEctions and wiring NOTE : there is only one connection per interface (RS232 or RS422 or RS485) 5. 4.1. RS232 connection: – Standard PC connection – Sub-D 9 pins connector – Pin 2 : – Pin 3 : –...
  • Page 8 nstallatIon nsIde 5. 5. c EriaL Link dEfaULt sEttings Baud rate: 9600 bauds Parity: none data: 8 bits Stop: 1 bit Slave: The serial link settings can be set from the control panel. 5. 6. H “ 2” ow to cHangE tHE sEriaL Link sEttings Available baud rate:...
  • Page 9 6. InStaLLatIon of modBuS tcP caRd 6. 1. ‘c ’ Lots LocaLisation The « Com-Slots » integrates all communication interfaces and it is located on the right side. Please, see on the manual of the concerned UPS to see the correct localisation of the «com slot 2» 6.
  • Page 10 DHCP mode by default. No IP address set by default Mode MODBUS TCP Port tcP 502 DISCOVERY TOOL Download AGILIPLUG utility from SOCOMEC web site. Unzip the file on your computer (only Windows) run AGILIPLUG Finder program SEARCHING UPS CONNECTED AGILIPLUG Finder lists all IP addresses of MODBUS TCP interface connected to network.
  • Page 11 7. conventIonS The table addresses are written in hexadecimal, beginning with ‘0x’. Some PLC systems request a relative address starting from 400 (0x0190) or 40001 (0x9C41), on this address it’s necessary to add the first address of the MODBUS table. 6.
  • Page 12 8. modBuS In SIngLe uPS unIt taBLe Start addresses table length in words modBuS functIon UPS Identification 0x1100 3 read Date and hours 0x1360 3 read UPS Configurations 0x1120 3 read UNIT Status (64 bits) 0x1143 3 read UNIT Alarm (80 bits) 0x114A 3 read unit measurements...
  • Page 13 Ingle UnIt UPs modbUs tables 8. 3. U 1100, 32 w dEntification ddrEss ords code description number address type Remarks i000 UPS identification 10 wordS 0x1100 1 word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char i010 UPS Description 6 wordS...
  • Page 14 UPs m Ingle UnIt odbUs ables 8. 6. U 1143, 4 w tatUs ddrEss ords code description address Remarks S048 Load on inverter 0x1143 S049 Load on auto. Bypass S050 Load on maintenance Bypass S051 Load not supplied S052 unit is available S053 Unit isolated from inst.
  • Page 15 UPs m Ingle UnIt odbUs ables code description address Remarks S080 Unit Start procedure progress 0x1145 S081 Unit maintenance bypass procedure progress S082 S083 Battery test interrupted S084 Battery test in progress S085 Battery test in stand-by S086 S087 S088 S089 S090 S091...
  • Page 16 UPs m Ingle UnIt odbUs ables 8. 7. U 114a, 4 w Larms ddrEss ords code description address Remarks a032 unit imminent stop 0x114A a033 Unit overload a034 Transfer blocked a035 transfer impossible a036 Insufficient Resources only on parallel a037 a038 a039 Rectifier critical...
  • Page 17: Table Of Contents

    UPs m Ingle UnIt odbUs ables code description address Remarks a071 a072 a073 a074 a075 a076 a077 a078 a079 a080 0x114D Preventive maintenance a081 a082 Maintenance bypass alarm a083 rotation phase fault a084 Rectifier or Bypass Input supply not OK a085 a086 a087...
  • Page 18: Code Description

    UPs m Ingle UnIt odbUs ables 8. 8. U 1220, 80 EasUrEmEnts tabLEs ddrEss words format format code description unit address t015=0 t015=1 m032 Output voltage U12 0x1220 m033 Output voltage U23 m034 Output voltage U31 m035 Output voltage L1 m036 Output voltage L2 m037...
  • Page 19 UPs m Ingle UnIt odbUs ables format format code description unit address t015=0 t015=1 m071 Inverter frequency x10 ##.# ##.# m072 Bypass input supply voltage U12 m073 Bypass input supply voltage U23 m074 Bypass input supply voltage U31 m075 Bypass input supply voltage V1 m076 Bypass input supply voltage V2 m077...
  • Page 20 UPs m Ingle UnIt odbUs ables 8. 9. U 1150; 1 w nabLEd ontroLs abLE ddrEss ords code description address Remarks v007 Eco-mode 0x1150 v008 Normal-mode v032 Unit Start procedure 0x1152 v033 Reserved v034 make unit available v035 Switch load to inverter v036 Switch load to mains v037...
  • Page 21 9. modBuS In moduLaR PaRaLLeL SyStem confIguRatIon 9. 1. r EmindEr In UPS parallel system configuration, there is only one MODBUS interface. The addresses mapping gives the pos- sibility to read data from each unit and system. There is no link between the MODBUS salve number and the unit number.
  • Page 22 odbUs tables In modUlar Parallel system confIgUratIon 9. 2. m odbUs tabLE in modULar ParaLLEL sYstEm table Start addresses table Length In words modbus function UPS Identification 0x0100 3 read Date and hours 0x0360 3 read UPS Configurations 0x0120 3 read UPS Status (48 bits) 0x0140 3 read...
  • Page 23 odbUs tables In modUlar Parallel system confIgUratIon 9. 7. U 0140, 3 w tatUs ddrEss ords code description address Remarks S000 Load supplied by inverter 0x0140 S001 Load on automatic bypass S002 Load on maintenance. Bypass S003 Load not supplied S004 Eco-mode S005...
  • Page 24 odbUs tables In modUlar Parallel system confIgUratIon 9. 8. U 0148, 2 w Larms ddrEss ords code description address Remarks a000 uPS imminent stop 0x0148 a001 UPS overload a002 UPS transfer blocked a003 uPS transfer impossible a004 UPS insufficient Resource a005 UPS Redundancy loss a006...
  • Page 25 odbUs tables In modUlar Parallel system confIgUratIon 9. 9. U 0200, 32 w EasUrEmEnts ddrEss ords format format code description unit address t015=0 t015=1 m000 Output voltage U12 0x0200 m001 Output voltage U23 m002 Output voltage U31 m003 Output voltage L1 m004 Output voltage L2 m005...
  • Page 26 odbUs tables In modUlar Parallel system confIgUratIon 9. 10. U 150, 2 w nabLEd ontroLs abLE ddrEss ords code description address Remarks UPS Start procedure 0xm150 Reserved Transfer load to inverter Transfer load to mains UPS load off Energy Saver ON Energy Saver OFF Eco-mode Normal mode...
  • Page 27 10. modBuS In PaRaLLeL SyStem wIth centRaLISed ByPaSS 10. 1. r EmindEr In UPS parallel system configuration, there is only one MODBUS interface. The addresses mapping gives the pos- sibility to read data from each unit and system. There is no link between the MODBUS salve number and the unit number.
  • Page 28 odbUs In Parallel system wIth centralIsed byPass 10. 2. m odbUs tabLE in ParaLLEL sYstEm witH cEntraLisEd bYPass table Start addresses table Length In words modbus function UPS Identification 0x0100 3 read Date and hours 0x0360 3 read UPS Configurations 0x0120 3 read UPS Status (48 bits)
  • Page 29 odbUs In Parallel system wIth centralIsed byPass 10. 7. U 0140, 3 w tatUs ddrEss ords code description address Remarks S000 Load supplied by inverter 0x0140 S001 Load on automatic bypass S002 Load on maintenance. Bypass S003 Load not supplied S004 Eco-mode S005...
  • Page 30 odbUs In Parallel system wIth centralIsed byPass 10. 8. U 0148, 2 w Larms ddrEss ords code description address Remarks a000 uPS imminent stop 0x0148 a001 UPS overload a002 UPS transfer blocked a003 uPS transfer impossible a004 UPS insufficient Resource a005 UPS Redundancy loss a006...
  • Page 31 odbUs In Parallel system wIth centralIsed byPass 10. 9. U 0200, 32 w EasUrEmEnts ddrEss ords format format code description unit address t015=0 t015=1 m000 Output voltage U12 0x0200 m001 Output voltage U23 m002 Output voltage U31 m003 Output voltage L1 m004 Output voltage L2 m005...
  • Page 32 odbUs In Parallel system wIth centralIsed byPass 10. 10. U 150, 2 w nabLEd ontroLs abLE ddrEss ords code description address Remarks UPS Start procedure 0xm150 Reserved Transfer load to inverter Transfer load to mains UPS load off Energy Saver ON Energy Saver OFF Eco-mode Normal mode...
  • Page 33 11. ByPaSS taBLe 11. 1. b f143, 4 w YPass tatUs ddrEss ords code description address Remarks S048 Load on inverter 0xF143 S049 Load on auto. Bypass S050 Load on maintenance Bypass S051 Load not supplied S052 S053 S054 Output switch 3 closed S055 S056 S057...
  • Page 34: Address Remarks

    yPass ables code description address Remarks S080 Starting 0xF145 S081 Unit maintenance bypass procedure progress S082 S083 S084 S085 S086 S087 S088 S089 S090 S091 Q4 closed S092 Local maintenance bypass Q5 clos. S093 Remote maintenance bypass closed S094 S095 S096 0xF146 Auxiliary input 1 active...
  • Page 35 yPass ables 11. 2. b f14a, 4 w YPass Larms ddrEss ords code description address Remarks a032 unit imminent stop 0xF14A a033 Unit overload a034 Transfer blocked a035 transfer impossible a036 Insufficient Resources only on parallel a037 a038 a039 a040 a041 Bypass critical a042...
  • Page 36: A080 Preventive Maintenance A081

    yPass ables code description address Remarks a071 a072 a073 a074 a075 a076 a077 a078 a079 a080 Preventive maintenance 0xF14D a081 a082 Maintenance bypass alarm a083 a084 a085 a086 a087 a088 a089 a090 a091 a092 a093 a094 Output since xx minutes on auto bypass Bypass General alarm a095 a096...
  • Page 37 yPass ables 11. 3. b f220, 80 YPass EasUrEmEnts tabLEs ddrEss words format format code description unit address t015=0 t015=1 m032 Output voltage U12 0xF220 m033 Output voltage U23 m034 Output voltage U31 m035 Output voltage L1 m036 Output voltage L2 m037 Output voltage L3 m038...
  • Page 38 yPass ables format format code description unit address t015=0 t015=1 m071 m072 Bypass input supply voltage U12 m073 Bypass input supply voltage U23 m074 Bypass input supply voltage U31 m075 Bypass input supply voltage V1 m076 Bypass input supply voltage V2 m077 Bypass input supply voltage V3 m078...
  • Page 39 12. moduLe taBLe 12. 1. m 143, 4 w odULE tatUs ddrEss ords code description address Remarks S048 Load on inverter 0xm143 S051 Load not supplied S052 Module is available S053 Module isolated from inst. S054 Output switch 2 closed S055 Rectifier ON S056...
  • Page 40 odUle ables code description address Remarks S080 Module Start procedure progress 0xm145 S081 S082 S083 Battery test interrupted S084 Battery test in progress S085 Battery test in stand-by S086 S087 S088 S089 S090 S091 S092 S093 S094 Q21 switch closed S095 Q22 switch closed S096...
  • Page 41 odUle ables 12. 2. m 14a, 4 w odULE Larms ddrEss ords code description address Remarks a032 unit imminent stop 0xm14A a033 Module overload a034 a035 a036 a037 a038 a039 Rectifier critical a040 Inverter critical a041 a042 Common critical a043 Fan alarm a044 Back feed protection open...
  • Page 42: A083 Rotation Phase Fault

    odUle ables code description address Remarks a071 a072 a073 a074 a075 a076 a077 a078 a079 a080 Preventive maintenance 0xm14D a081 a082 a083 rotation phase fault a084 a085 a086 a087 a088 a089 a090 a091 a092 a093 a094 unit General alarm a095 a096 Fly Wheel disconnected 0xm14E...
  • Page 43 odUle ables 12. 3. m 220, 80 odULE EasUrEmEnts tabLEs ddrEss words format format code description unit address t015=0 t015=1 m032 Output voltage U12 0xm220 m033 Output voltage U23 m034 Output voltage U31 m035 Output voltage L1 m036 Output voltage L2 m037 Output voltage L3 m038...
  • Page 44 odUle ables format format code description unit address t015=0 t015=1 m071 Frequency inverter x10 ##.# ##.# m072 m073 m074 m075 m076 m077 m078 ###.# ###.# m079 ambient t° °c ##.# ##.# m080 Vdc + 0xm250 m081 m082 Battery voltage string + ###.# m083 m084...
  • Page 45 13. annexe 13. 1. modbUs tcP c wEb PagE user name: root Password: public NETWORK CONFIGURATION DHCP enabled by default It is necessary to reboot the device after NETWORK settings modification, Delphys green power - Ref.: IOMDGPJB0910-GB_11...
  • Page 46 ANNEXE 13. 2. modbUs tcP ida sPEcification The JBUS frames below are only examples: REQUEST BY MASTER IN MODE JBUS/MODBUS RTU Original frame: 01 03 1034 0003 40C5 Encapsulated frame: 0046 0000 0006 01 03 1034 0003 where: 0046 corresponds to the transaction number 0000 corresponds to the protocol identifier 0006...
  • Page 48 Socomec: our innovations supporting your energy performance 3,200 independent manufacturer employees % of sales revenue experts worldwide dedicated to R&D dedicated to service provision Your power management expert POWER POWER POWER ExPERt sWitCHing mOnitORing COnvERsiOn sERviCEs The specialist for critical applications •...