● The following conditions are required to display a time chart.
• Only one LOG number is selected.
• The target LOG is set to "Trace".
• The "logging/trace done flag" of the target LOG is "ON".
When the stop trigger is detected, the "Trace stop trigger monitor flag" and "Trace data
acquisition done flag" turn on.
● The time chart cannot be activated during executing the logging/trace operation.
● The indication of the "Buffer free space" of the LOG that has been set to Trace is always
zero.

5.3.2 Explanation of Time Chart Monitor

The time chart window is composed of the following parts.
WUME-FP7CPULOG-04
5.3 Trace Monitor (Time Chart)
5-7