System Data Registers Relating To Logging/Trace Operation - Panasonic FP7 Series User Manual

Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

3.2 Operation Check Using Logging/Trace Monitor
Device
Name
number
SR105
Logging/trace error
No SD card free
SR106
space
Device/trigger
SR107
setting error
Tracing stop trigger
SR108
monitor
Trace data
SR109
acquisition
completed
(Note 1)
The above device numbers are those for LOG0. System relay numbers vary depending on LOG
numbers as shown in the table below.
LOG
No.
100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
SR
No.
109 119 129 139 149 159 169 179 189 199 209 219 229 239 249 259

3.2.3 System Data Registers Relating to Logging/Trace Operation

System data registers (SD)
Device
Name
number
SD100
Buffer free space
Buffer overflow
SD120
counter
(Note 1)
The above device numbers are those for LOG0. System data register numbers vary depending on
LOG numbers as shown in the table below.
LOG
No.
100 101 102 103 104 105 106 107 108 109 110
SD
No.
120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135
3-6
Operation
● The buffer overflow relay turns off at the end of scan when a vacancy
occurs in the buffer as writing data into an SD memory card progresses,
and the buffer overflow counter is cleared to 0. Also, after the occurrence
of buffer vacancy, data logging is executed once the logging trigger
condition is met.
● This relay is always on when buffer full occurs as the stop condition when
selecting Trace for the application.
● Turns on when an error is detected during the logging/trace operation
and stops logging/trace.
● Turns on when an SD memory card is running out of free space during
the logging/trace operation and stops logging/trace.
● Turns on when an error is detected in set values during the startup
operation. The logging/trace error relay SR105 also turns on. At that time,
the active relay does not turn on because the logging/trace function
cannot be activated.
● Monitors a registered trace stop trigger when executing tracing. Turns on
when conditions are met. This relay is always off when selecting Logging
for the application.
● Turns on after logging data for a specified number of times after detecting
the trace stop trigger during the execution of trace. This relay is always
off when selecting Logging for the application.
0
1
2
3
to
to
to
to
Operation
● Stores free space of buffer memory during logging. This is always zero
when selecting Trace for the application.
● Increments the value (+1) when the buffer overflow occurs. This is
always zero when selecting Trace for the application.
0
1
2
3
4
5
6
7
to
to
to
to
4
5
6
7
8
9
10
11
12
to
to
to
to
8
9
10
11
12
111
112 113 114 115
WUME-FP7CPULOG-04