1

Mechanical Installation

Warning!
During installation the following installation and safety instructions as well as the instructions in
the additional manuals on CD must be complied with.
During assembly, make sure that no forei g n particles (e. g . filin g s, dust, wires, screws, tools) can
get inside the frequency inverter.
Mount the devices with sufficient clearance to other components so that the cooling air can
circulate freely. Avoid soiling by grease and air pollution by dust, aggressive gases, etc.
b
b1
x
a1
a
a2
x
100 mm
x
b
b1
x
a1
a
a2
x
x
100 mm
20
20
ACT 201 (up to 3.0 kW) and ACT 401 (up to 4.0 KW)
c
b1
c1
ACT 201 (4.0 to 9.2 kW) and ACT 401 (5.5 to 15.0 kW)
c
c1
Insert the long side of the fixing plate
in the heat sink.
Screw the fixing plate to the mounting
plate.
top M4x20
bottom M4x60
Screw the fixing brackets to the heat
sink of the frequency inverter and the
assembly panel.
06/07