Hitachi Highly WHP13100AEDPC9EQ Installation Manual

Rotary compressors

Advertisement

Quick Links

Hitachi Highly 
Rollkolbenverdichter
Rotary Compressors
Spezifikation
Installation Manual
WHP13100AEDPC9EQ
R 410A
DC Verdichter
900 - 7200 min-1
RIES GmbH, Rudolf-Diesel-Str. 10, D 64569 Nauheim, GERMANY
Phone: +49 6152 9741 0, Fax: +49 6152 9741 21, Email: info@ries-gmbh.de, Website: www.ries-gmbh.de

Advertisement

loading

Summary of Contents for Hitachi Highly WHP13100AEDPC9EQ

  • Page 1 Hitachi Highly  Rollkolbenverdichter Rotary Compressors Spezifikation Installation Manual WHP13100AEDPC9EQ R 410A DC Verdichter 900 - 7200 min-1 RIES GmbH, Rudolf-Diesel-Str. 10, D 64569 Nauheim, GERMANY Phone: +49 6152 9741 0, Fax: +49 6152 9741 21, Email: info@ries-gmbh.de, Website: www.ries-gmbh.de...
  • Page 2 Table of Contents First: WHP13100AEDPC9EQ Specifications ——————— 1~4 1. Application range 2. Compressor specifications 3. Motor parameters 4. General characteristics 5. Parts and drawings list Second: the heat pump water heater dedicated compressor use benchmark ————— 5~15 third: the basis and rules of acceptance —————————————— 16 1.
  • Page 3 S U B J E C T M o d e l W H P 1 3 1 0 0 A E D P C 9 E Q S P E C I F I C A T I O N PAGE:1/30 SCOPE T h i s s p e c i f i c a t i o n i s a p p l i e d t o S H A N G H A I H I T A C H I H e a t pump water heater...
  • Page 4 *.COP= Heating capacity Motor input *.Rated Capacity and input are measured with HITACHI inverter circuit by secondary Refrigerant calorimeter Methods of JIS B8606 by Shanghai Hitachi Electrical Appliances Co., Ltd. Allowable capacity should be more than 95% of the rated capacity and allowable input should be less than 107% of rated motor input.
  • Page 5 S U B J E C T M o d e l W H P 1 3 1 0 0 A E D P C 9 E Q S P E C I F I C A T I O N PAGE:3/30 Inductance Ld(mH)...
  • Page 6 S U B J E C T M o d e l W H P 1 3 1 0 0 A E D P C 9 E Q S P E C I F I C A T I O N PAGE:4/30 PARTS AND DRAWING LIST PARTS NAME...
  • Page 7 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:5/30 COMPRESSOR CRITERIA 1 Strictly observe the specification The compressor should be used in specifications written in this “compressor specification”...
  • Page 8 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:6/30 Table 2 Item Operating Envelope Discharge pressure...
  • Page 9 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:7/30 raph 1 Condensing temperature 70℃...
  • Page 10 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:8/30 8 Discharge pipe temperature Discharge pipe temperature is measured at a distance 300mm from the surface of compressor and should be less than 110℃.
  • Page 11 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:9/30 14 Impurities in refrigerating system (1)The weight of residue on the inside surface of the heat exchanger and tube should be less than 0.01g/m .
  • Page 12 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:10/30 18 Purge parts with dry nitrogen or dry air to remove remains in parts (dust, detergent, etc.) before assembly of system.
  • Page 13 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:11/30 Moving tubes to the moving parts; minimum clearance 12.7mm(1/2”) Moving tubes to non-moving parts;...
  • Page 14 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:12/30 (6)The compressor can’t be used in the place with corrosive atmosphere such as hot spring and chemical warehouse.
  • Page 15 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:13/30 (14) SHEC will not take any responsibility against accident that is caused by the accessories equipped by yourselves.
  • Page 16 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:14/30 It is necessary to install a dryer to dehumidify the residual moisture mixed in the refrigerant in the cycling system.
  • Page 17 H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:15/30 (27)The fuse or/and breaker should be equipped in the main circuit. (28) The thickness of the refrigerating system using tube the tube thickness as followed external diameter(mm)
  • Page 18 C h e c k u p o n D e l i v e r y PAGE:16/30 1. Basis for Checking upon Delivery The Performance test will be carried out in accordance with this “compressor Specification”. The Safety Performance in accordance with GB4706.1 Safety of household and similar electrical appliances General requirements and GB 4706.17 Safety of household and similar electrical appliances Particular requirements for motor-compressor.
  • Page 19 17/30...
  • Page 20 18/30...
  • Page 21 . 19/30...
  • Page 22 20/30...
  • Page 23 21/30...
  • Page 24 22/30...
  • Page 25 23/30...
  • Page 26 24/30...
  • Page 27 25/30...
  • Page 28 26/30...
  • Page 29 27/30...
  • Page 30 28/30...
  • Page 31 Anwendungshinweise für DC Inverter Kompressoren zur Drehzahlregelung Instruction for DC inverter compressor rotation speed control Drehzahländerung / <= Speed change rate: 133min-1/s Max und Min Drehzahl in den einzelnen Spezifikationen Max and min speed is showed in the specification Vom Start zur gewünschten Drehzahl / From starting to normal running Rotation speed Drehzahl...
  • Page 32 30/30...
  • Page 33 Specification Revision Record Page in Date Revision Reason Conclusion Date Spec...