H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A
Item
Discharge pressure
MPa
Suction Pressure
MPa
Compressor case bottom
temp
Motor winding temp
Accumulator temp
Ambient temp
Table 2
Operating Envelope
4.762 MAX
(condensing temperature:70℃)
0.272~1.652
(Evaporation Temperature:-30℃~25℃) It can also be 0.101~
0.272 MPa when in transition , but should not be used when
it is less than 0.101MPa
99℃or below and 6 degrees
higher than condensing
temperature
R a t e d v o l t a g e : 105℃
MAX
Higher than outlet pipe of evaporator
Meet for the condition of above mentioned motor winding temp.
(see graph
R.Voltage±10%:
120℃ MAX
PAGE:6/30