Page 2
Table of Contents 1.WH11500VSDPC9EQ ———————1~4 1.Application area 2.Compressor Specification 3.Motor Parameter 4.Parts and drwing list 5.General characterics 2.Heatpump water heater dedictaed compressor referen 5~15 3. . Acceptan —————————————— 16 1.Acceptance basis 2.Acceptance rules 4. Drawings —————————————— 17~30 5. . Modification of Specificati ————————...
Page 3
S U B J E C T M o d e l W H P 1 1 5 0 0 V S D P C 9 E Q S P E C I F I C A T I O N PAGE:1/30 SCOPE T h i s s p e c i f i c a t i o n i s a p p l i e d to SHANGHAI HIGHLY Heat pump water heater compressor.
Page 4
S U B J E C T M o d e l W H P 1 1 5 0 0 V S D P C 9 E Q S P E C I F I C A T I O N PAGE:2/30 *.COP= Heating capacity Motor input...
Page 5
S U B J E C T PAGE:3/30 M o d e l W H P 1 1 5 0 0 V S D P C 9 E Q S P E C I F I C A T I O N Inductance Ld(mH)...
Page 6
S U B J E C T M o d e l W H P 1 1 5 0 0 V S D P C 9 E Q S P E C I F I C A T I O N PAGE:4/30 PARTS AND DRAWING LIST PARTS NAME...
Page 7
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:5/30 COMPRESSOR CRITERIA 1 Strictly observe the specification The compressor should be used in specifications written in this “compressor specification”...
Page 9
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:7/30 R410A R452B - 3 5 - 3 0 - 2 5...
Page 10
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:8/30 8 Discharge pipe temperature Discharge pipe temperature is measured at a distance 300mm from the surface of compressor and should be less than 110℃.
Page 11
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:9/30 14 Impurities in refrigerating system (1)The weight of residue on the inside surface of the heat exchanger and tube should be less than 0.01g/m .
Page 12
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A 热 泵 热 水 器 专 用 压 缩 机 使 用 基 准 PAGE:10/30 18 Purge parts with dry nitrogen or dry air to remove remains in parts (dust, detergent, etc.) before assembly of system.
Page 13
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:11/30 Moving tubes to the moving parts; minimum clearance 12.7mm(1/2”) Moving tubes to non-moving parts;...
Page 14
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:12/30 (6)The compressor can’t be used in the place with corrosive atmosphere such as hot spring and chemical warehouse.
Page 15
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:13/30 (14) SHEC will not take any responsibility against accident that is caused by the accessories equipped by yourselves.
Page 16
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:14/30 It is necessary to install a dryer to dehumidify the residual moisture mixed in the refrigerant in the cycling system.
Page 17
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:15/30 (27)The fuse or/and breaker should be equipped in the main circuit. (28) The thickness of the refrigerating system using tube the tube thickness as followed External diameter(mm)
Page 18
C h e c k u p o n D e l i v e r y PAGE:16/30 1. Basis for Checking upon Delivery The Performance test will be carried out in accordance with this “compressor Specification”. The Safety Performance in accordance with GB4706.1 Safety of household and similar electrical appliances General requirements and GB 4706.17 Safety of household and similar electrical appliances Particular requirements for motor-compressor.