Download Print this page

Hitachi Highly WHP13100AEDPC9EQ Installation Manual page 16

Rotary compressors

Advertisement

H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A
It is necessary to install a dryer to dehumidify the residual moisture mixed in the
refrigerant in the cycling system. The specially defined molecular-sieve dryer is
advised.
(21) Use the refrigerant of specified brand. When the refrigerant not specified used, it will
possibly cause trouble of the performance and reliability of the compressor by the
impurities in the refrigerant.
(22) The lead wires should be connected to hermetic terminals without being touched on the
surface of the compressor.
(23) Be careful of avoiding oxide scale while soldering during assembly of refrigerating
system.
(for example: flow or fulfill dry nitrogen)
(24) The quantity and kind of contamination (the process materials) in the cycle should
be grasped and managed. Carry on reliability test that input contamination a lot than
anticipated contamination quantity.
(25) To avoid water and impurity into he refrigeration system and make sure no leakage of
refrigerant during the operating course. It's required to direct the erector and
maintenance man of air-conditioner.
(26) The start-up current and torsion of compressor
Adjust the start-up current of the compressor to get enough torsion by inverter. Confirm
and measure the start-up current if change the parts and design.
PAGE:14/30