Fujitsu AUXG07KVLA Manual page 362

2-unit multi-split type
Hide thumbs Also See for AUXG07KVLA:
Table of Contents

Advertisement

 Function setting procedure
1.
Connect the power supply of the outdoor unit.
2.
To enter the function setting mode, while holding down the POWERFUL and SET TEMP.
buttons, press the RESET button.
3.
Select the function number by pressing the
button is pressed, it switches between the right digit and the left digit.
4.
Proceed to the setting number by pressing the POWERFUL button. (To return to the function
number selection, press the POWERFUL button again.)
5.
Select the function number by pressing the
ton is pressed, it switches between the right digit and the left digit.
1-2. Indoor unit (setting by wireless remote controller)
POWERFUL
SET TEMP. (
)
RESET
Change digit
or the
buttons. Each time the 10°C HEAT
or the
button. Each time the 10°C HEAT but-
Change digit
- (05-10) -
Function setting
mode display
Change digit
1. Function settings (for indoor unit)

Hide quick links:

Advertisement

Table of Contents
loading