counter to count down.
Figure 6.5: Home return configuration tab (the Controller Configuration Window)
Home Return Configuration Tab (Controller Configuration Window)
In the Home Return Configuration Tab of the Controller Configuration Window, the user can configure origin
position signals, home return speed for searching origin position signals and searching origin position modes of all
axes.
1. Select appropriate ORG Active Logics
a. Select Active HIGH in ORG Active Logics panel means the effective logic level of the origin position signal
is High level.
b. Select Active LOW in ORG Active Logics panel means the effective logic level of the origin position signal
is LOW level.
2. Select appropriate Home Return Velocity Settings
a. Select Starting Velocity in Home Return Velocity panel means the controller will search origin position
signals at the Starting Velocity specified by velocity profile setting functions.
b. Select Maximum Velocity in Home Return Velocity panel means the controller will search origin position
signals at the Maximum Velocity specified by velocity profile setting functions.
3. Select appropriate ORG Signal Searching Mode Settings
a. Select Single Direction in Home Return Modes panel means the controller will stop output pulses once it
receives the origin position signals.
b. Select Repeat Search in Home Return Modes panel means the controller will return back for a litter distance
when it receives the origin position signals at the Starting Velocity specified by velocity profile setting functions,
and then search the origin position signals again at the Starting Velocity values.