Regulations For Commissioning Installations For France; Technical Data - DeDietrich EASYLIFE CFU 36 F30 User Manual

Oil-fired boiler
Table of Contents

Advertisement

3 Technical specifications
3.1.3

Regulations for commissioning installations for France

F30 biofuel is available in France from 01/07/2022.
Decree No. 2022-8 of 5 January 2022 of the Ministry for Energy Transition currently in force relating to F30 biofuel stipulates
that:
It is prohibited to install equipment which uses fuels emitting over 300 g CO
New boilers running on biofuels shall be permitted, provided that this threshold is respected.
Repair work on existing boilers shall still be possible.
3.2

Technical data

Tab.5
Technical parameters for boiler space heaters
Product name
Condensing boiler
Low-temperature boiler
(1)
B1 boiler
Cogeneration space heater
Combination heater
Rated heat output
Useful heat output at rated heat output and high temperature regime
Useful heat output at 30% of rated heat output and low temperature re­
gime
(1)
Seasonal space heating energy efficiency
Useful efficiency at rated heat output and high temperature regime
Useful efficiency at 30% of rated heat output and low temperature re­
gime
(1)
Auxiliary electricity consumption
Full load
Part load
Stand-by
Other specifications
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
(1) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature
(at heater inlet).
(2) High temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
Tab.6
Burner specifications
Burner type
Oil flow rate
F30 flow rate
10
CFU
eq/kWh LHV based on life cycle assessment.
2
Prated
P
(2)
4
P
1
ƞ
s
ƞ
(2)
4
ƞ
1
elmax
elmin
P
SB
P
stby
P
ign
Q
HE
L
WA
NO
x
See
The back cover for contact details.
Unit
kg/h
kg/h
CFU 36
F30
No
Yes
No
No
No
kW
37
kW
37.2
kW
11.6
%
86
%
87.3
%
90.9
kW
0.156
kW
0.064
kW
0.004
kW
0.109
kW
--
GJ
124
dB
63
mg/kWh
118
CFU 36 F30 CFU 46 F30
F10N3–1.40 F10N3–1.50
3.4
4.2
3.5
4.4
7740570 - v04 - 03112022
CFU 46
F30
No
Yes
No
No
No
46
46.4
14.5
86
86.9
90.7
0.160
0.066
0.004
0.122
--
154
65
118

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easylife cfu 46 f30

Table of Contents