Shutting Down The Boiler; Frost Protection; Settings; Personalising The Control Panel - DeDietrich EASYLIFE CFU 36 F30 User Manual

Oil-fired boiler
Table of Contents

Advertisement

4. Check the hydraulic pressure in the installation indicated on the user interface.
Important
Recommended hydraulic pressure between 0.15 and 0.2 MPa (1.5 and 2.0 bar).
5. Confirm the selection by pressing the selector
If the boiler is connected to a domestic hot water tank, the boiler begins an automatic venting cycle that lasts around 3
minutes and is repeated each time the power is cut. If there is a problem, an error message is displayed on the home
screen.
6. If an error message is displayed on the home screen, contact the installer.
5.3

Shutting down the boiler

The boiler must be shut down in certain situations, for example during any intervention on the equipment. In other situations,
such as an extended absence period, we recommend that the
benefit from the boiler anti-blocking function and to protect the installation from frost.
To shut down the boiler:
1. Switch off the boiler.
See also
Selecting the operating mode, page 18
Periods of absence or going on holiday, page 22
5.4

Frost protection

Caution
The frost protection function does not work if the boiler is powered off.
Caution
The integrated protection system only protects the boiler, not the heating system.
Caution
Have the boiler and heating system drained by a qualified professional if the home is left empty for a long period of
time and there is a chance of frost.
Important
To prevent the radiators and the installation from freezing in places where that risk exists (e.g. in a garage or an
equipment room), we recommend connecting an outdoor temperature sensor to the boiler.
If the temperature of the water in the boiler falls too much, the integrated protection device switches itself on. This device
functions as follows:
Tab.13
Water tem­
Operating description
perature
< 7 °C
The circulating pump starts up and shuts down if the water temperature is higher than 10 °C. The circulating
pump continues to run for a short time.
< 4°C
The boiler starts up and shuts down if the water temperature is higher than 35 °C.
6

Settings

6.1

Personalising the control panel

It is possible to personalise the control panel by modifying the basic settings.
7740570 - v04 - 03112022
.
System holiday mode operating mode is used in order to
6 Settings
CFU
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easylife cfu 46 f30

Table of Contents