4.10 Operation environment
• Height above sea level ≤1000 M
• Operation temperature range -10〜+40°C
• Air relative humidity is below 90 %(20°C)
• Preferable site the machine some angles
above the floor level, the maximum angle
does not exceed 15°C
• Protect the machine against heavy rain
AND against direct sunshine.
• The content of dust, acid, corrosive gas in
the surrounding air or substance cannot
exceed normal standard.
• Take care that there is sufficient ventilation
during welding. There must be at least 30cm
free distance between the machine and wall.
4.11 Operation Notices
• Read Section 1 carefully before starting
to use this equipment.
51
ADVANCEMULTI205P
4.0
1.6
180-210
6.0
1.2
220-250
6.0
1.6
220-240
8.0
1.6
250-300
12.0
1.6
300-400
www.strata.co.nz
18-20
35-45
24-25
50-60
20-24
37-50
25-26
60-65
26-28
65-75
• Connect the ground wire with the machine
directly.
• Ensure that the input is single-phase:
50/60Hz, 110V/220V ±10%.
• Before operation, none concerned people
should not be around the working area and
especially children. Do not watch the arc in
unprotected eyes.
• Ensure good ventilation of the machine to
improve Duty Cycle.
• Turn off the engine when the operation finished
for energy consumption efficiency.
• When power switch shuts off protectively
because of failure. Don't restart it until problem
is resolved. Otherwise, the range of problem
will be extended.
• In case of problems, contact your local dealer if
no authorized maintenance staff is available!
18-22
18-22
18-22
16-24
18-22
16-24
18-22
16-24
18-22
16-24