Advertisement

Quick Links

ADVANCEARC 160/200
MMA (STICK) WELDERS
OPERATING INSTRUCTIONS
230V 50HZ
IGBT
DIRECT
SPIKE/
VOLTAGE
CONSTANT
LIFT TIG
POWER FACTOR
10A PLUG
INTELLIGENT
IP23 CORROSION
MULTI VOLTAGE
SINGLE
INVERTER
CURRENT
GENERATOR
REDUCTION
CURRENT
(OPTIONAL
CORRECTION
(ADVANCEARC 160)
PROTECTION
& SALT SPRAY
110 - 230V
PHASE
TECHNOLOGY
OUTPUT
SAFE
DEVICE
TORCH)
SYSTEM
RESISTANT
www.strata.co.nz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVANCEARC 160 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Strata ADVANCEARC 160

  • Page 1 ADVANCEARC 160/200 MMA (STICK) WELDERS OPERATING INSTRUCTIONS 230V 50HZ IGBT DIRECT SPIKE/ VOLTAGE CONSTANT LIFT TIG POWER FACTOR 10A PLUG INTELLIGENT IP23 CORROSION MULTI VOLTAGE SINGLE INVERTER CURRENT GENERATOR REDUCTION CURRENT (OPTIONAL CORRECTION (ADVANCEARC 160) PROTECTION & SALT SPRAY 110 - 230V...
  • Page 2 ADVANCEARC 160 • ADVANCEARC 200 Congratulations on your new Strata product! The Strata range from Euroquip uses latest technology design and engineering to produce welding products that combine market leading value and features with durability. Designed for discerning operators who seek professional results and product quality without the price tag of a full professional setup.
  • Page 3: Table Of Contents

    ADVANCEARC 160 • ADVANCEARC 200 Contents Know Your Machine............5 Quick Start Guide..............6 Available Parts & Accessories...........7 Wiring Diagram..............8 Care & Maintenance............9 Electrodes.................9 Effects of MMA Welding Various Metals......10 Other Knowledge & Resources........10 Safety................11 Warranty.................19 www.strata.co.nz...
  • Page 4 ADVANCEARC 160 • ADVANCEARC 200 MMA (STICK) WELDERS • ADVANCEARC 160 • ADVANCEARC 200 • The Advance Series of MMA (Stick) Welders offer the latest IGBT and PFC (Power Factor Correction) technology for smart operators. Increased reliability, performance for harsh and demanding conditions are some of the benefits surrounding the Advanced Series Welders.
  • Page 5: Know Your Machine

    VRD protection is enabled standard for the overheating (due to exceeding duty cycle) is detected AdvanceArc 160/200. If it is not required, the feature and protection is activated. can be disabled by a Strata service dealer. When protection is activated, welding output will be disabled until the safety system senses the overload Tips & Tricks has reduced sufficiently and indicator lamp goes out.
  • Page 6: Quick Start Guide

    Quick Start Guide - Welder Installation Electrical Connection Note: This polarity connection configuration is valid for most GP (General Purpose) MMA electrodes. There are variances to - The ADVANCEARC 160 is designed to operate on a this. If in doubt, check the electrode specifications or consult the 10A 230V AC power supply. electrode manufacturer.
  • Page 7: Available Parts & Accessories

    Supercito 4.0mm Electrodes (450mm) ETCPH7740 Supercito 4.0mm Electrodes (450mm) ETCPH7750 Supercito 5.0mm Electrodes (450mm) ETCPH7750 Supercito 5.0mm Electrodes (450mm) ETCPH56S25 Tenax 56S 2.5mm Electrodes (350mm) ETCPH56S25 Tenax 56S 2.5mm Electrodes (350mm) ETCPH56S32 Tenax 56S 3.2mm Electrodes (350mm) ETCPH56S32 Tenax 56S 3.2mm Electrodes (350mm) ETCPH56S40 Tenax 56S 4.0mm Electrodes (450mm) ETCPH56S40 Tenax 56S 4.0mm Electrodes (450mm) ETCPH56S50 Tenax 56S 5.0mm Electrodes (450mm) ETCPH56S50 Tenax 56S 5.0mm Electrodes (450mm) PDL15 Plug, 3 Pin 15A 250V straight PDL15 Plug, 3 Pin 15A 250V straight These accessories listed are available from your Strata Supplier. Refer to the Strata Catalogue, your Strata Supplier or look online at www.strata.co.nz for other accessories and consumables available. www.strata.co.nz...
  • Page 8: Wiring Diagram

    ADVANCEARC 160 • ADVANCEARC 200 Wiring Diagram www.strata.co.nz...
  • Page 9: Care & Maintenance

    ADVANCEARC 160 • ADVANCEARC 200 Care & Maintenance Keep your Welding Machine genuine replacement parts. Do not use modified or non-genuine parts. in Top Condition The ADVANCEARC 160/200 does not require any special maintenance, however the user should take Storing the Welder...
  • Page 10: Effects Of Mma Welding Various Metals

    ADVANCEARC 160 • ADVANCEARC 200 Effects of MMA Welding Various Materials High Tensile and Alloy Steels hydrogen types for high tensile steel, cellulose types The two most prominent effects of welding these for welding large diameter pipes, etc. The range of...
  • Page 11: Safety

    ADVANCEARC 160 • ADVANCEARC 200 Safety Store and Retain this Manual General Safety Warnings Retain this manual for the safety warnings and pre- 1. Maintain labels and nameplates on the welder. These cautions, assembly, operating, inspection, mainte- carry important information. If unreadable or miss- nance and cleaning procedures. Write the product’s ing, contact Euroquip for a replacement.
  • Page 12 ADVANCEARC 160 • ADVANCEARC 200 Safe practices are outlined in the European Standard 9. Ensure that the unit is placed on a stable location EN60974-1 entitled: Safety in welding and allied pro- before use. cesses. WARNING! WARNING! If this unit falls while plugged in, severe injury, Only use safety equipment that has been ap- electric shock, or fire may result.
  • Page 13 ADVANCEARC 160 • ADVANCEARC 200 Arc Rays can Burn Eyes and Skin 4. If working on a metal wall, ceiling, etc., prevent ignition of combustibles on the other side by moving the combustibles to a safe location. If DANGER! relocation of combustibles is not possible, desig- Arc rays from the welding process produce...
  • Page 14 ADVANCEARC 160 • ADVANCEARC 200 4. Disconnect input power before installing or ser- ground or the work surface. Do not touch hold- vicing this equipment. Lock input power, discon- ers connected to two welding machines at the nect switch open, or remove line fuses so power same time or touch other people with the holder cannot be turned on accidentally.
  • Page 15 ADVANCEARC 160 • ADVANCEARC 200 12. Use only well-maintained equipment. Repair or Fire & Explosive Risks replace damaged parts as soon as practical. WARNING! 13. In confined spaces or damp locations, do not use Sparks and spatter fly off from the welding arc. a welder with AC output unless equipped with a The flying sparks and hot metal, weld spatter, voltage reducer.
  • Page 16 ADVANCEARC 160 • ADVANCEARC 200 Cylinders WARNING! Gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully. 1. Protect compressed gas cylinders from exces- sive heat, mechanical shocks, and arcs.
  • Page 17 ADVANCEARC 160 • ADVANCEARC 200 www.strata.co.nz...
  • Page 18 ADVANCEARC 160 • ADVANCEARC 200 www.strata.co.nz...
  • Page 19: Warranty

    Registered warranty period for the ADVANCEARC 160/200: The decision that an issue with a product qualifies as a warranty claim is made at the sole jurisdiction of Euroquip. Commercial Use: 36 Months...
  • Page 20 Congratulations on your new STRATA product. We are proud to have you as our customer and will strive to provide you with the best service and reliability in the industry. This product is backed by our extensive warranty and world-wide service network. To locate your nearest distributor or service agency visit www.

This manual is also suitable for:

Advancearc 200

Table of Contents