Download Print this page
Full Gauge Controls TO-711F Instruction Manual

Full Gauge Controls TO-711F Instruction Manual

Oven time and temperature controller

Advertisement

Quick Links

Have this manual in your hand
using the
FG Finder
app.
BEFORE INSTALLING THE CONTROLLER, WE RECOMMEND THAT YOU FULLY READ THE INSTRUCTION
MANUAL TO PREVENT POSSIBLE DAMAGE TO THE PRODUCT.
THROUGH CONTINUOUS DEVELOPMENT, FULL GAUGE CONTROLS RESERVES THE RIGHT TO CHANGE
THIS MANUAL INFORMATION AT ANY TIME WITHOUT PRIOR NOTICE.
THIS CONTROLLER IS NOT RESPONSIBLE FOR SAFETY WITH RESPECT TO ANY FLAME SENSOR, GAS
VALVE, OR SPARK IGNITER OF WHICH NEED TO HAVE SAFETY CERTIFICATES (RECOGNIZED IGNITION AND
GAS MODULE) IN ITS APPLICATION FOR FINAL USE. THE FLAME SENSOR, THE GAS VALVE OR SPARK
IGNITER IN THIS CONTROL WILL BE CONSIDERED SEPARATELY FROM THE THERMON CONTROLLER.
1. DESCRIPTION
Thermostat and timer for forced convection oven automation. The
wood-fired ovens, configured through its installation menu. Using the recipe mode, you have 20 settings for
temperature control, cooking time and steam injection, making the oven ready for the most varied types of cooking.
TO-711F
The
lets you rotate the turbine rotation direction to improve roast uniformity and when necessary
temporarily turn off the turbine with a long key press. The controller features 3 steam injection modes, automatic
lighting of the oven, and an internal buzzer that warns, for example, the end of the roast. It also allows the use of
external audible alarm and thermal protection temperature sensor of the turbine, which prevents overheating. The
ThermOn line was developed and produced as high quality raw material and stands out for its unique and
differentiated design, friendly and intuitive interface that facilitates its operation and configuration. Features lockout
function prevents third parties from changing parameters, airtight front that offers high protection against dirt,
moisture and more.Product compliant with UL Inc. (United States and Canada).
2. APPLICATIONS
Baking ovens, stoves;
3. TECHNICAL SPECIFICATIONS
Power supply / Approximate consumption
Operating temperature / Control temperature
Temperature sensor
Thermal protection sensor
Resolution
Digital Input
Flame sensor
Relay outputs
External audible alarm (buzzer) outputs
Product dimensions / Cutout dimensions (mm)
Operating humidity
Ratings outputs for UL Applications
1 A Resistive,100,000 Cycles
Resis
tance
1 / Gas 1 / Alarm 1
0.5 A
1/8 HP, 100,000 Cycles
Resis
tance
2 / Gas 2 / Alarm 2
1 A
1/8 HP, 30,000 C les
Steam valve / Ignition
0.5 A Pilot load, 30,000 Cycles
1 A General purpose, 100 Cycles
Lightbulb
1 A Tungst , 30,000 C
1/8 HP, 30,000 Cycles
Fan
1 /
Fan
2
0.5 Pilot load, 30,000 Cycles
4. INTRODUCTION
Heating on indication LED;
Fan on indication LED;
TO-711F
Timer activated LED
indicator;
Steam output on LED
SET
indicator;
Quick touch: Temperature
a n d c o o k i n g t i m e
adjustment;
SET
Press and Hold: Access to the
advanced configuration;
Quick touch: Preset selection;
REC
Press and Hold: Preset configuration;
Quick touch: Steam activation;
Press and Hold: Steam activation time
adjustment;
* When
[i10]
- Enables standby mode = YES
[i11]
**When
- Enables manual control of turbine
output = YES
OVEN TIME AND TEMPERATURE CONTROLLER
Heating
Steam
Lighting
Fan
TO-711F
provides control of gas, electric or
±
TO711F: 85~2 Vac
40
10% (*) (50-60Hz) / 10VA
ac/Vdc +
TO711FL: 12~24V
0
to 131 F
º (0
to
55° ) / 1
C
4 to 932 F
Type J or K thermocouple (sold separately)
Fan PTC (sold separately)
E1: door micro switch input or external
E2 : flame sensor input
7
relay ou
tputs: 5 (3)A / 250Vac 1/8HP
75 x 75 x 100 ( x xD) / 67 2 x 67 2
W H
10
to
90% UR (
without conde
TO711F
240 Vac
Pilot load
, 100,000 C les
yc
240 Vac
240 Vac
Ge
neral purpose, 100,000 C
ycles
240 Vac
yc
240 Vac
240 Vac
240 Vac
en
ycles
240 Vac
240 Vac
240 Vac
Lower display: Indicates the cooking time or parameter
configuration;
Upper display: Indicates the
temperature measured by the
sensor or parameter configuration;
Te m p e r a t u r e u n i t s L E D
indicator;
Functions lock LED indicator;
REC
Preset use LED indicator;
Quick touch: Decreases parameter
value when in programming mode;
Press and Hold: Activates or
deactivates the controller stand-by;
Quick touch: Increases parameter value
when in programming mode;
**Press and Hold: Activates or deactivates
turbine output;
Quick touch: Timer activation;
KEY FUNCTIONS
SET
Each key has an LED to indicate its
LED
function. When the LED is on, it
KEY
indicates that the key is active and
can be pressed.
TO-711F
Buzzer
Timer
Presets
Functions
Serial
Block
programming
5. INSTALLATION CONFIGURATION
Access the installat
d
isplayed. When
to enter
Use the
<
or
>
keys to select the desired function. The value can be edited with a quick touch on the
<
>
Use the
ou
to change the value and press the
value and return to the functions menu. To leave the configuration menu and return to the normal operating
m o d e ( t e m p e r a t u r e i n d i c a t i o n ) , p r e s s
5.1 Installation setup table
FUN
FUNCTION
[CoD]
Access Code (231)
[i01]
Oven type selection
[i02]
Temperature sensor type
U n i t s e l e c t i o n o f
[i03]
temperature
Language selection
10% / 10VA
[i04]
° (-1
0 to 500 C
° )
1ºC / 1ºF
Enables external sound alarm
[i05]
(buzzer)
alarm
(buzzer)
12Vcc / 30mA (max)
Internal audible alarm (buzzer)
.
.
[i06]
volume
nsation)
TO711FL
24Vac / Vdc
[i07]
D
igital input signal type
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
[i08]
Digital input mode
24Vac / Vdc
24Vac / Vdc
[i0 ] 9
Enable fan thermal protection
Enables stand-by oven
[i
10
]
functionality
Enables manual control of
[i
11
]
turbine output
6. OPERATION
6.1 Oven: electric
In this operating mode the controller keeps the heating output on until the oven reaches the oven temperature
setpoint (SP). The heating output will be activated again when the temperature drops below the setpoint minus the
hysteresis
[F04]
.
6.2 Oven: gas
In this operating mode the controller automates / monitors the flame ignition and thus the heating of the oven through
the activation of the gas output, ignition module, and flame sensor input. The controller keeps the heating on until the
oves reaches the oven temperature setpoint (SP).
Heating will be activated again when the temperature drops below the setpoint minus the Hysteresis
The controller permanently monitors the flame sensor to ensure the safe operation of the gas-fired oven. In this way,
if there are any abnotmalities, errors
indicated. For more information, check item 9 (Signaling).
6.3 Oven: wood
In this operating mode the heating output works as an upper threshold alarm, indicating when the temperature
exceeds the value adjusted in Oven Temperature setpoint (SP). The audible alarm is also activated to warn the user
about the overheating. The output and audible alarm are switched off when the temperature drops below the Oven
Temperature setpoint (SP) inus the Hysteresis
pressed.
IP 65
FRONT
Protection
E251415
level
ion configuration menu by pressing the
[CoD]
SET
is d
isplayed press the
dsdet
key again (quick touch). Use the
the access code 231
and press
dddd
SET
(quick touch) again when ready.
SET
dsse
key with a quick touch when ready to save the configured
SET
d d d d
( p r e s s a n d h o l d ) u n t i l
DESCRIPTION
Required when you want to change
installation setup parameters.
Selects the control type of the oven:
[ELE,]
= Electric Oven
[GAS,]
= Gas-fired Oven
[LEN,]
= Wood-fired Oven
Defines the type of temperature sensor to
be used with the controller.
Selects the temperature unit the controller
will use for its operation
Selects the language the controller will use
to display messages:
[Port]= Portuguese
[,EnG]= English
[,ESP]= Spanish
Enables or disables the external audible
alarm (buzzer). If enabled, the internal
audible alarm (buzzer) will be disabled.
Selects the sound intensity of the internal
audible alarm (buzzer)
[Min,]= low volume
[Med,]= medium volume
[HiGh]= high volume
[,NO,]- normally open contact (NO)
[,NC,]- normally closed contact (NC)
Allows you to configure whether the digital
input will be used as an input for a door
sensor or as a digital input for high
temperature alarm:
[door] = Door sensor input;
[ALAr]= High temperature external alarm
input.
NOTE: When configured as a high
temperature alarm input, the other
functionalities related to the door sensor
consider that the door is always closed.
If enable, monitors fan temperature. In
case of overheating, enters error mode,
switching off the outputs of the controller.
[ON,]
= Fan thermal protection enable
[OFF]
= Fan thermal protection disable.
Enables stand-by mode (switching off
control functions)
Enabled, it allows the turbine output to be
deactivated or activated by the user
manually, always respecting the times set
[F27]
in parameters
and
[Er4]
- Flame Sensor shorted with the burner and
[F05]
or when the
SET
dddd
key for 4 seconds until
[Func]
is
<
>
o
r
keys
dddd
SET
key.
[ - - - - ]
i s d i s p l a y e d .
M N
I
MAX UNIT DEFA
-
0
9999
0
-
ELE LEN
GAS
-
tc_J tc_H
tc_J
-
ºC
°C
ºF
-
PORT ESP
PORT
-
OFF ON
OFF
-
MIN HIGH
HIGH
-
NO
NC
NO
-
door Alarm
door
-
OFF
ON
OFF
-
NO
YES
NO
-
NO
YES
NO
[F28]
.
[F04]
.
[Er5]
- Lack of Flame are
SET
dddd
key in the controller's front panel is

Advertisement

loading

Summary of Contents for Full Gauge Controls TO-711F

  • Page 1 When is d isplayed press the dsdet key again (quick touch). Use the keys THROUGH CONTINUOUS DEVELOPMENT, FULL GAUGE CONTROLS RESERVES THE RIGHT TO CHANGE to enter the access code 231 and press dddd (quick touch) again when ready.
  • Page 2 6.4 Default Mode (standard) In this operating mode the controller performs the gas type control, 7.4 Functions lock however the flame sensor is ignored and the controller will not monitor flame presence. The controller will not detect To enable / disable the function lock, press <...
  • Page 3 Delay to activate the se . c [f21] Measure: parameter is valid when automatic steam is automatic steam Contact Full Gauge Controls. [F20] adjusted in parameter Defines the minimum time interval between Measure: steam activations, i.e. once the steam output Contact Full Gauge Controls.
  • Page 4 = 1000 Ω (T - 5K) = máx 550 Products manufactured by Full Gauge Controls, as of May 2005, have a two (2) - year waranty directly with the factory and = Resistance at rated 1 2 3 4 18 17 16 15 14 13 12 11 10 one (1) year before the reseller network, counted as of the date of consigned sale as stated on the invoice.

This manual is also suitable for:

To711fl