Installing the RS485 to additional power supplies
NOTE: For an E1 system there is no externally connected RS485.
NOTE: For structures lager than the above additional external communications need to
be added between the RS485 surge board and the translator boards in each of the
additional power supplies.
NOTE: For systems larger than E2 daisy chaining between the translator boards is
required.
E1+1, D1+1 and A1+1
Translator
Board#2
NOTE: Translator boards are located in power supply enclosures NOTE:
The controller translator board is to be set to zero.
Translator
Board#1
Located in
power
supplies
E2, D2 and A2
Translator
Board#1
1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732)
Document No: 9100-127-1958-99 Rev F
RS485
Junction
Board
RS485
Junctio n
Board
919-3119 Fax: (732) 751-5778 www.dialight.com
RS485
Located in
Controller