K) If the Photocell mode transition alarm (18 hour alarm) is not needed as an
alarm this selection can disable it.
NOTE: Typically used where there long day or night operations.
Selecting YES: If the photocell does not detect day or night after 18 hours, the
system will alarm after 18 hours and will switch to Day mode. To clear this alarm the
system requires a local reset or a forced operation change locally or remotely.
Selecting NO: After 18 hours of not transitioning the system will log an event in the
log but the system will continue to operate normally based on light conditions. No
alarm via dry contact or mod bus will be generated.
Trans PEC Alrm = YES
u/d=chg, enter=done
Use "UP" and "DWN" buttons to change from "NO" to "YES", and then press "ENTR."
L) The Beacon can be made steady burn in Red night mode
Once the selection for the Beacon steady red Night is completed the next screen to be
displayed is the "Config Type".
NOTE: Typically used outside of the US. FAA regulations require the beacon to be
flashing so most typical installation will have this selection set to "NO" to ensure a
flashing beacon.
BCN Steady RNite= NO