Download Print this page

Dialight Medium Intensity Quick Start Manual page 14

Advertisement

Screen: Mode of operation – Day or Night
NOTE: These modes change according to the user's photocell operation. There are no
options for preprogramming mode change times.
Mode: Options are Day or Night , T= controller temperature (C)
Active: Options are Wht or Red
NOTE: On this screen the controller can be forced in DAY or NIGHT (using the
push buttons located under the down button marked White and Red). NOTE:
S3 will blink till system is restored to normal operation
MODE: Night T=X C
ACTIVE: RED 864
Status Screen - Alarms:
This screen allows the user access to the Alarm Log. By pressing the "ENTR" button,
current and previous alarms the system has encountered are able to be viewed, starting
with the most current alarm. Alarms can be scrolled through using the "UP" and "DWN"
buttons. Each alarm occurrence is dated and time stamped. Up to 999 alarm entries
can be stored in the controller.
NOTE: If an Alarm is found, the Status screen will change from "NORMAL" to "ALARM"
thus indicating there is an active Alarm.
By pressing "ENTR" you will be able to view alarm logs. Time stamps are actual times
that the alarm occurred. Refer to interpretation of the logs for further details.
Status: Normal
'Enter' to view Alrm
Date and Time Screen - Setting the real time clock:
By selecting "ENT" the user can set the actual time and date of the Base Controller.
NOTE: Date and time settings are stored in the controller; if power is lost, internal
battery backup ensures settings will not be erased.
MMM DD,YY "Time"
'Enter' to set Clock
1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732)
Document No: 9100-127-1958-99 Rev F
MODE: Night Forced
'Clear to restore
Status: ALARM
'Enter' to view Alrm
919-3119 Fax: (732) 751-5778 www.dialight.com