READ AND FOLLOW ALL SAFETY INSTRUCTIONS
DO NOT let any supply cords touch hot
surfaces higher than cord ratings.
DO NOT mount near gas or electric heaters
Equipment should be mounted in locations and
at heights where it will not be subjected to
tampering by unauthorized personnel.
The
use
of
accessory
recommended by the manufacturer may cause
unsafe conditions.
DO NOT use this equipment for other than
intended use.
DO NOT look into the Infrared (IR) LEDs. These
five IR LEDs on top of the unit (if applicable) will
not appear to be ON, but can be verified using
most digital cameras.
Pictures
are
commissioning the install. Failure to
provide could VOID all warranties
SAVE THESE INSTRUCTIONS!!
Introduction:
This manual is for orientation of the controller, configuration and definitions of the Dual
Strobe system or Dual Strobe + Infrared (IR) system.
Refer to the installation manual for the following information
Installing the Controller and the pre drilled holes
Dimensions of the Controller
Securing the cables to the structure
Connection of either AC or DC input voltages
Connection of the Side lights and calibration
Photocell connections
Flashhead connections for both the 4 conductor and the 8 conductor versions
Proper bonding of the Strobe cable
Mounting the Flashhead.
Medium Intensity Quick Start Manual
equipment
not
required
for
Instructions must be kept with the system installed
South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax:
Document No: 9100-127-1958-99 Rev F
Release Date: 10/8/15
The operation and maintenance must be carried
out by authorized personnel.
Repairs and Installation must only be carried out
by a qualified electrician.
Only genuine Dialight replacement parts must be
used when unforeseen repairs are required.
Observe the national safety rules and regulations
during installation!
Earth Grounding is required throughout the
install process. Failure to do so could void all
warranties!
No alterations should be done without the
agreement from Dialight Corp. Alterations other
Than written in this manual will void all
warranties.
(732) 751-5778 www.dialight.com
1501 Route 34

Advertisement

loading

Summary of Contents for Dialight Medium Intensity

  • Page 1 • Equipment should be mounted in locations and at heights where it will not be subjected to • Only genuine Dialight replacement parts must be tampering by unauthorized personnel. used when unforeseen repairs are required. • accessory...
  • Page 2 • Resetting, ext sync option, and serial numbers • Replacement part numbers • Display Events and Alarm Descriptions • Alarm list and possible causes System Overview: 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 3 Gen5 dual red/white + Infrared (IR) with 48VDC • D1CW-FH409 (Flash Head) input , 48volt sidelights and 8 conductor flash head • D1CW-CTR449 (Controller/Supply) cable required 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 4 WARNING: For Color Codes not shown the installer must take note of the colors used for these connections since it is required that all A, Common and B terminals be connected the same throughout the system. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 5 E2, D2 and A2 Translator Translator Board#2 Board#1 NOTE: Translator boards are located in power supply enclosures NOTE: The controller translator board is to be set to zero. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 6 NOTE: See electrical parameters for power consumption Attach output of Photocell to side light monitor board (Marker) board J4 Connect the RS485 to the Junction Board when additional power supplies are connected. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 7 NOTE: See electrical parameters for power consumption Attach output of Photocell to monitor board (Marker) board J4 Connect the RS485 to the Junction Board when additional power supplies are connected. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 8 A red only systems the countdown starts at 45. NOTE: In some cases this screen will go back to the Startup screen if synchronization was faulty. Initial 15 Flashes In Process 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 9 “YES” indicates an external GPS is being used, “NO” is the standard configuration without an external GPS. Press “ENTR” after selection. Ext GPS = NO u/d=chg, enter=done 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 10 NOTE: Additional sidelight monitor boards are available for special applications; most configurations will only have one board and this will remain set to “1” Number of SD BDs=1 u/d=chg, enter=done 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 11 NOTE: This step should only be selected if all tiers of sidelights are fully installed and connected to the controller. RECAL L810 = NO u/d=chg, enter=done 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 12 NOTE: Typically used outside of the US. FAA regulations require the beacon to be flashing so most typical installation will have this selection set to “NO” to ensure a flashing beacon. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 13 NOTE: If the installer selects 3 beacons and only 1 is powered AL1 (config ERR) will be lit and recorded in the alarm log. Tower Style: X X 86X ,X 810 B y 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 14 NOTE: Date and time settings are stored in the controller; if power is lost, internal battery backup ensures settings will not be erased. MMM DD,YY “Time” ‘Enter’ to set Clock 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 15 Press ‘Enter’ Key to view event log. After this display when pressing the up button the Config display is the next one shown. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 16 This can be confirmed by monitoring AL8 on the dry contact board. Once the AL8 is off the system is in Night mode. Wait for 15 flashes and then press the TEST RED button. MLI ‘CLR’ to exit push RED BTN 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 17 NOTE: If the test is not completed due to prompts not being followed, tests will time out after 5 minutes and display: Manual LI TEST LIT NOT DONE 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 18 13. SDLT Comm CLR 14. PCE LOST CLR 15. 1 ALL L810 TX CLR 16. 1 864 R25% ACT 17. 1 864 R25% CLR 18. LIT log end 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 19 Trans is set white or to NO red fails Dry Contact monitoring Installation: Cable requirements: A minimum of 22AWG wire should be used for connecting the relays 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 20 Wattage below is with no side lights attached; wattage from side lights must be added. Nominal Supply Voltage (VAC) Conditions Peak Watts 230Vac 50/60Hz Day mode (E1 system) 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 21 340mA Max Required for E1 and larger structures with L810 side lights being installed. For use with: D1RW-C17-009-CTR D1RW-C17-409-CTR Part Number Voltage Range Watts RTO-1R07 120-240Vdc 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 22 Serial Numbers: The serial numbers of the fixtures being installed are located on the Dialight label. Dialight refers to the serial numbers as Date Codes. The Date Codes are set up as The following YY,DDD, S/N. YY= the year it was produced DDD= Julian day of the year S/N= a number of either 3 or 4 digits.
  • Page 23 Document No: 9100-127-1958-99 Rev F Replacement Part Numbers: D1xW-C13-409-CTR 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 24 Document No: 9100-127-1958-99 Rev F D1RW-C13-009-CTR: 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 25 Document No: 9100-127-1958-99 Rev F D1xW-C14-409-CTR: 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 26 Document No: 9100-127-1958-99 Rev F D1RW-C14-009-CTR 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 27 Document No: 9100-127-1958-99 Rev F WARNING: Unit should not be lifted from the tabs. - Dome should not be removed nor manipulated. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 28 AC input D1RW9005RA models Replacement Side Light D7502-SLM Monitor for AC side lights Replacement Side Light D7500-SLM Monitor for DC side lights Replacement Relay Board D7600-RLY 1501 Route 34 South, Farmingdale, NJ 07727 Fax: (732) 751-5778 www.dialight.com...
  • Page 29 Status Number, Act or Clr displayed Highest was last NOTE: The above are separate screens shown on the LCD both logs are individually accessible Alarm List: 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 30 Check TX,RX Check: That the yellow and RLY Comm 1 S7 on LCD lit Communication and Tx_En if black wires are connected Alarm logged flashing 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 31 Check wring in junction failed Check wiring to side light REVISION HISTORY REV ECO No. DATE ------ 8/28/13 13676 10/13/13 23828 2/9/15 29987 10/8/15 35652 5/24/16 68542 6/19/20 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...