Manual Lighting Inspection Test for Firmware Versions B6 or higher:
The user can perform a manual lighting inspection to ensure proper operation of the
system in its entirety.
NOTE: Discreet and Modbus alarms will be generated during this test, if NOC is actively
monitoring at the time of test, they will see the generated alarms.
Test will time out after 2 minutes of no user input during the manual test. The test relies
on user input to complete the necessary checks.
NOTE: A lighting inspection can be done remotely but the Auto lighting inspection is
required. The auto does not require covering of the photocell or pressing the selected
mode during the auto test.
System needs to be in Day mode before test is started
Press "ENTR" to initiate LI test
Press enter
Press' TEST WHITE' button located under the 'Down' on the LCD control board A
series of test will be automatically performed.
Cover photocell; wait until beacon turns Red or White Night.
This can be confirmed by monitoring AL8 on the dry contact board. Once the AL8 is off
the system is in Night mode.
Wait for 15 flashes and then press the TEST RED button.
Manual LI TEST
'enter' to Test
MLI 'CLR' to exit Push
WHT BTN
Manual LI TEST IN
PROCESS WHT
MLI 'CLR' to exit
push RED BTN