AXIS D3110 Connectivity Hub Installation Installation To watch this video, go to the web version of this document. help.axis.com/?&piaId=72056§ion=install...
Get started Find the device on the network To find Axis devices on the network and assign them IP addresses in Windows®, use AXIS IP Utility or AXIS Device Manager. Both applications are free and can be downloaded from axis.com/support.
Secure passwords Important Axis devices send the initially set password in clear text over the network. To protect your device after the first login, set up a secure and encrypted HTTPS connection and then change the password. The device password is the primary protection for your data and services. Axis devices do not impose a password policy as they may be used in various types of installations.
AXIS D3110 Connectivity Hub Configure your device Configure your device Set up rules for events To learn more, check out our guide Get started with rules for events. Trigger an action 1. Go to System > Events and add a rule. The rule defines when the device will perform certain actions. You can set up rules as scheduled, recurring, or manually triggered.
Page 7
Set up an MQTT broker and get the broker’s IP address, username and password. • Set up AXIS Motion Guard in the camera. Set up the MQTT client in the camera 1. In the camera’s device interface, go to System > MQTT > MQTT client > Broker and enter the following information:...
Page 8
AXIS D3110 Connectivity Hub Configure your device Host: Broker IP address Client ID: For example Camera 1 Protocol: The protocol the broker is set to Port: The port number used by the broker The broker Username and Password 2. Click Save and Connect.
Page 9
AXIS D3110 Connectivity Hub Configure your device 3. Go to MQTT subscriptions and add a subscription. Enter the following information: Subscription filter: Motion Subscription type: Stateful QoS: 0, 1 or 2 4. Click Save. Create a rule in the connectivity hub for MQTT subscriptions 1.
AXIS D3110 Connectivity Hub Configure your device Name: Open lock Condition: I/O > Digital input is active Select Use this condition as a trigger Port: Button Action: I/O > Toggle I/O once Port: Lock State: Active Duration: 10 s 3. Click Save.
AXIS D3110 Connectivity Hub The device interface The device interface To reach the device interface, enter the device’s IP address in a web browser. Show or hide the main menu. Access the product help. Change the language. Set light theme or dark theme.
AXIS D3110 Connectivity Hub The device interface Audio Device settings Input: Turn on or off audio input. Shows the type of input. Input type: Select the type of input, for instance if it’s internal microphone or line-in. Power type : Select power type for your input.
AXIS D3110 Connectivity Hub The device interface Listen and record Click to listen. Click to start a continuous recording of the live audio stream. Click again to stop the recording. If a recording is ongoing, it will resume automatically after a reboot.
Page 14
AXIS D3110 Connectivity Hub The device interface Click to play the recording. Click to stop the recording.
Page 15
AXIS D3110 Connectivity Hub The device interface Click to show more information and options about the recording. Set export range: If you only want to export part of the recording, enter from when to when. Click to delete the recording.
• Activate license with a key: If the app requires a license, you need to activate it. Use this option if your device doesn’t have internet access. If you don’t have a license key, go to axis.com/applications. You need a license code and the Axis product serial number to generate a license key.
Page 17
AXIS D3110 Connectivity Hub The device interface Network IPv4 Assign IPv4 automatically: Select to let the network router assign an IP address to the device automatically. We recommend automatic IP (DHCP) for most networks. IP address: Enter a unique IP address for the device. Static IP addresses can be assigned at random within isolated networks, provided that each address is unique.
Page 18
One-click cloud connection One-click cloud connection (O3C) together with an O3C service provides easy and secure internet access to live and recorded video from any location. For more information, see axis.com/end-to-end-solutions/hosted-services. Allow O3C: • One-click: The default setting. Press and hold the control button on the device to connect to an O3C service over the internet.
Page 19
Authentication failed: Sends a trap message when an authentication attempt fails. Note All Axis Video MIB traps are enabled when you turn on SNMP v1 and v2c traps. For more information, see AXIS OS Portal > SNMP. • v3: SNMP v3 is a more secure version, which provides encryption and secure passwords. To use SNMP v3, we recommend you to activate HTTPS, as the password is then sent through HTTPS.
Page 20
To install test firmware or other custom firmware from Axis on the device, you need a custom-signed firmware certificate. The certificate verifies that the firmware is approved by both the device owner and Axis. The firmware can only run on a specific device which is identified by its unique serial number and chip ID.
Page 21
AXIS D3110 Connectivity Hub The device interface Users Add user: Click to add a new user. You can add up to 100 users. Username: Enter a unique username. New password: Enter a password for the user. Passwords must be 1 to 64 characters long. Only ASCII printable characters (code 32 to 126) are allowed in the password, for example letters, numbers, punctuation, and some symbols.
Page 22
AXIS D3110 Connectivity Hub The device interface Add a condition: Click to add an additional condition. Action: Select an action from the list and enter its required information. For information about specific actions, see Get started with rules for events.
Page 23
RSA is the preferred method during negotiation, followed by ECDSA, ED25519, and DSA. Make sure to enter the right MD5 host key that is used by your SFTP server. While the Axis device supports both MD5 and SHA-256 hash keys, we recommend using SHA-256 due to stronger security over MD5. For more information on how to configure an SFTP server with an Axis device, go to the AXIS OS Portal.
Page 24
IoT integration and is used in a wide variety of industries to connect remote devices with a small code footprint and minimal network bandwidth. The MQTT client in Axis device firmware can simplify integration of data and events produced in the device to systems which are not video management systems (VMS).
Page 25
AXIS D3110 Connectivity Hub The device interface Connect message Specifies if a message should be sent out when a connection is established. Send message: Turn on to send messages. Use default: Turn off to enter your own default message. Topic: Enter the topic for the default message.
Page 26
AXIS D3110 Connectivity Hub The device interface Add subscription: Click to add a new MQTT subscription. Subscription filter: Enter the MQTT topic that you want to subscribe to. Use device topic prefix: Add the subscription filter as prefix to the MQTT topic.
Page 27
AXIS D3110 Connectivity Hub The device interface Note The selected codecs must match the call recipient codec, since the recipient codec is decisive when a call is made. • Audio direction: Select allowed audio directions. Additional • UDP-to-TCP switching: Select to allow calls to switch transport protocols from UDP (User Datagram Protocol) to TCP (Transmission Control Protocol) temporarily.
Page 28
DNS. Windows SMB/CIFS names are not supported. • Network share: Enter the name of the shared location on the host server. Several Axis devices can use the same network share, since each device gets its own folder.
Page 29
AXIS D3110 Connectivity Hub The device interface Onboard storage Important Risk of data loss and corrupted recordings. Do not remove the SD card while the device is running. Unmount the SD card before you remove it. Unmount: Click to safely remove the SD card.
Page 30
Delete user: Delete the user. You can’t delete the root user. By creating an ONVIF user, you automatically enable ONVIF communication. Use the username and password for all ONVIF communication with the device. For more information see the Axis Developer Community at axis.com. ONVIF media profiles An ONVIF media profile consists of a set of configurations that you can use to change media stream settings.
Page 31
AXIS D3110 Connectivity Hub The device interface Current state: Shows the current state of the port. The input or output is activated when the current state is different from the normal state. An input on the device has an open circuit when it’s disconnected or when there is a voltage above 1 V DC.
Severity: Select which messages to send when triggered. CA certificate set: See the current settings or add a certificate. Plain config Plain config is for advanced users with experience of Axis device configuration. Most parameters can be set and edited from this page. Maintenance Restart: Restart the device.
AXIS D3110 Connectivity Hub Specifications Specifications Product overview To watch this video, go to the web version of this document. help.axis.com/?&piaId=72056§ion=product-overview-d3110 Power connector RJ45 ethernet connector 2x microphone ports Audio out 2x I/O connectors MicroSD card slot 2x USB ports...
Flashes red for firmware upgrade failure. SD card slot For SD card recommendations, see axis.com. microSD, microSDHC, and microSDXC Logos are trademarks of SD-3C LLC. microSD, microSDHC, microSDXC are trademarks or registered trademarks of SD-3C, LLC in the United States, other countries or both.
Page 35
AXIS D3110 Connectivity Hub Specifications Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, through an event or from the product’s webpage. 6-pin terminal block Function...
Page 36
AXIS D3110 Connectivity Hub Specifications Power connector 2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
Using firmware from the active track is recommended if you want to access the newest features, or if you use Axis end-to-end system offerings. The LTS tracks are recommended if you use third-party integrations, which are not continuously validated against the latest active track.
Axis device. Check all cabling and reinstall the device. Possible IP address conflict The static IP address in the Axis device is used before the DHCP server sets a dynamic address. with another device on the...
AXIS D3110 Connectivity Hub Troubleshooting Performance considerations The following factors are the most important to consider: • Heavy network utilization due to poor infrastructure affects the bandwidth. • Running multiple activities at the same time can affect the audio performance.