Error message
E34
E37
E40
E51
E55
E58
7.3
Checklist for rectifying faults
The correct machine equipment for the material and process gas in use is a fundamental require-
ment for perfect operation!
Legend
Collective interference signal light illuminates
 Excess temperature, welding machine
Allow the machine to cool down whilst still switched on
 Welding current monitoring device triggered (stray welding currents flowing across the protective
earth). The error must be reset by switching the machine off and on again.
Welding wire is touching electrically conductive casing parts (check wire guide, has the welding
wire sprung off the wire spool?).
Check for a correct mounting of the welding lead. Fit the feeder clamp of the welding lead as
close as possible to the arc.
Excess temperature signal light illuminates
 Excess temperature, welding machine
Allow the machine to cool down whilst still switched on
40
Possible cause
Electronics error
Temperature error
Motor fault
Earth fault (PE error)
Failure of a mains phase
Short circuit in welding circuit
Symbol
Description
Fault/Cause
Remedy
Remedy
Switch the machine off and on again.
If the error persists, notify service department
Allow the machine to cool down
Check wire feed mechanism,
switch the machine off and on again, inform the
service department if the fault persists.
Connection between welding wire and machine
casing
Switch off the machine and check the mains volt-
age
Switch off the machine and check welding current
leads for correct installation, e.g. by placing the
electrode holder in an insulated position; detach
current lead from degaussing.