REMARKS ON INSTALLATION
REMARKS ON INSTALLATION
Please note that:
Please note that:
• •
the installation must be carried out by qualified
the installation must be carried out by qualified
personnel;
personnel;
• •
the appliance must be installed and used in
the appliance must be installed and used in
compliance with all local and national law and
compliance with all local and national law and
with European regulations; The Italian reference
with European regulations; The Italian reference
standard is UNI 10683; in France it is necessary
standard is UNI 10683; in France it is necessary
to observe the instructions of the DTA (Document
to observe the instructions of the DTA (Document
Technique
Technique
Technique), www.cstb.fr;
Technique), www.cstb.fr;
• •
if the product is installed in a condominium, the
if the product is installed in a condominium, the
appliance must be approved by the administrator;
appliance must be approved by the administrator;
• •
if the product is installed in public premises, check
if the product is installed in public premises, check
and follow the local regulations applicable to this
and follow the local regulations applicable to this
type of installation.
type of installation.
Below are a few general instructions which, however,
Below are a few general instructions which, however,
do not obviate the need to comply with local regulations
do not obviate the need to comply with local regulations
and do not imply any liability on the installer's job.
and do not imply any liability on the installer's job.
Bear in mind that the stove is sealed, in other words, if it
Bear in mind that the stove is sealed, in other words, if it
is installed correctly with the air inlet pipe connected to
is installed correctly with the air inlet pipe connected to
the outside, it takes in most of the air from the outside.
the outside, it takes in most of the air from the outside.
In every country check whether there are any particular
In every country check whether there are any particular
installation conditions allowed for sealed stoves.
installation conditions allowed for sealed stoves.
Checking the suitability of the room of
12

installation

The room must have a volume of at least 30 m
The floor must be able to bear the weight of the
product and its accessories* (see the note in the
paragraph on heat protection).
Level the appliance.
In Italy, pursuant to the UNI 10683 standard, the
appliance can also be installed in bedrooms or in
rooms which already include a product that takes
in combustion air from the same room, provided
that the air inlet is connected to the outside.
Do not install the product in rooms where there is
a risk of fire or explosion.
In Italy, verify the compatibility pursuant to the UNI
10683 and UNI 7129 standards in the presence of
gas-fired products.
NOTE
The smoke outlet diameter does not match the chimney system diameter. The chimney system must
be sized in accordance with the national and local regulations.
In particular (this is not an exhaustive list), refer to the EN 13384, EN 1443, EN 1856, EN 1457
standards and to all local regulations.
d'Application
d'Application
Référence
Référence
INSTALLATION
Protection from heat and safety clearances
The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
The appliance must be installed in accordance with
the following safety instructions:
- minimum clearance of 15 cm at the sides and 10 cm
at the back from flammable materials;
Avis
Avis
- no flammable materials may be kept closer than 80
cm from the front of the appliance.
If the product is installed with a wooden wall or a wall
made of other flammable material, the flue must be
appropriately insulated.
If the product is installed on a flammable and/or
combustible floor, or on a floor incapable of bearing
its load*, we recommend placing a steel or glass plate
under the stove to distribute the load.
Contact the retailer for this type of optional feature.
Positioning the product
The product is designed to operate in all climate
conditions. In special circumstances, such as strong
wind, the safety devices may intervene to switch the
.
3
appliance off.
Contact the authorised Edilkamin Technical Assistance
Centre.
INSTALLER