INSTALLING THE OpTIONAL FAN KIT
the CUBIrA and CUBIrA Cs are designed for heating
water and the room in which they are installed.
they heat the room by means of radiation and natural
convection, without the use of a fan.
However, an optional fan kit is available from your
reseller if you want to be able to heat the room up more
quickly.
the kit is composed of a fan with electrical equipment.
to install the kit:
• remove the back panel (1) by slackening off its
two bolts (2)
• fit the fan (3) in the back panel and secure it with
two bolts
• hook up the thermostat and electrical power
supply
Further details are provided in the assembly
instructions supplied with the kit itself.
8

INSTALLATION

2
3
1
IF YOU DO NOT INSTALL THE
OpTIONAL FAN KIT, YOU MUST
OpEN THE pANEL (C) UNDER THE
TOp.
C
THE pARTS OF THE
MANUAL ON INSTALLATION
ARE FOR THE USE OF
QUALIFIED pERSONNEL
Only work on electrical parts when
disconnected from the electrical power
source.

Advertisement

loading

This manual is also suitable for:

Cubira 12 cs