Protocol
Click [Set] button to save the configuration.
Serial Communication Protocol
[Panasonic, Standard]
Set the serial communication protocol for the RS422 terminal.
You can select either Panasonic or Standard.
Factory settings: Panasonic
Connector Selector
[RS422, RS232C]
Select [RS422] or [RS232-C].
[Note]
This can only be configured when [Serial Communication Protocol] is set to [Standard].
Factory settings: RS422
Baud Rate
[9600bps, 38400bps]
You can select a baud rate for serial communication.
[Note]
This can only be configured when [Serial Communication Protocol] is set to [Standard].
Factory settings: 9600bps
Camera Address
[Auto, 1, 2, 3, 4, 5, 6, 7]
Configure the camera ID in Daisy Chain connection to a controller.
Select [Auto] and the camera ID will be assigned automatically based on the order of camera connection.
If you select any number from 1 to 7, it will be assigned to the specified camera number.
[Note]
This can only be configured when [Serial Communication Protocol] is set to [Standard].
Factory settings: Auto
96