RESTRICTIONS IN USE

Only use the MINAC solely for its intended purposes under safe conditions and in
proper surroundings. Take great care when using the equipment. Heat only electrical
conductive materials. The presence of combustible materials involves a risk of fire.
The MINAC systems provide the following output power limitations for continuous
use and intermittent duty:
MINAC 25, 25 Twin
MINAC 50/80
The maximum output powers are attainable only with low Q - magnetic steel. The
maximum duty factor is 0.5 and the maximum cycle time is 10 minutes. This means
that during a selected cycle, the unit can run at maximum output power only half of
the time (to a maximum of five minutes).
© For reproduction rights, see cover page.
Equipment
Continuous use
Revision A
31 January 2005
Intermittent duty
25 kW
50 kW
40 kW
80 kW