Indications/Limitations during Power On
The purpose of these limitations is to achieve an optimal combination of maximum
output power and sufficient overload protection of the equipment.
Low frequency current limit
The voltage across the transformer has reached a preset maximum level for
the current load and frequency level, preventing further increases in output
power.
High frequency current limit
The output current (going through the transistors) has reached a preset
maximum level for the current load and frequency level, preventing further
increases in output power.
Maximum AC Current Limit
The output current has reached a preset maximum level, preventing further
increases in output power.
Maximum DC Power Limit
The DC power has reached a preset maximum level, preventing further
increases in output power.
Output reduced by EOR
The extended operating range (EOR) function has reduced the output to a
secure level for the current cooling water flow and temperature, preventing
further increases in output power.
Messages During Normal Operation
Ready
The unit is ready for operation. Operate a POWER ON device.
Power On
The output power is turned on.
DC Power
DC power is the current mode of operation.
AC Current
AC current is the current mode of operation.
Timer Active
The timer function is active.
Sequence Active
The sequence function is active.