Normal Stop; Emergency Stop - EFD MINAC 25 Twin User Manual

Mobile induction heating equipment
Table of Contents

Advertisement

MINAC Systems
USER MANUAL
63860.doc
6.4

Normal Stop

1. Turn the output power off by pressing the POWER OFF button on the operating
panel or an equivalent actuator on the ECU, or by releasing the button on the
HHT handle.
2. Turn off the main disconnector.
3. When the MINAC is turned off, a built-in magnetic valve closes the water flow to
the converter. Any external inlet/outlet water valves should be closed when the
equipment is left unsupervised for a time (some hours).
6.5

Emergency Stop

If an Emergency Stop input is generated while an ECU is used, the alarm message
"Stop" appears on the footer display. See 5.1.1 The power output of the MINAC is
switched off and all power-on functions of the MINAC are blocked.
To perform local emergency switching off, simply turn off the main disconnector on
the MINAC's operating panel.
© For reproduction rights, see cover page.
If the equipment is to be kept or transported in areas
where there is a risk of low temperatures and damage
from freezing, drain the cooling system. Set the MAIN
switch to the ON position and deactivate the "auto water
shut off" system before supplying compressed air to the
water inlet tailpiece (refer to 6.3.2). Keep the outlet
tailpiece open — Do not use a snap-action valve.
Revision A
31 January 2005
NOTE:
Page 32