IDEAL LOGIC+ SYSTEM2 S15 Installation & Servicing page 68

Table of Contents

Advertisement

1.6
GENERAL INFORMATION
BOILER PUMP
The boiler pump will operate briefly as a self-check once every
24 hours, regardless of system demand.
MINIMUM CLEARANCES
Clearance of 165 mm (6
1
/
") above, 100 mm (4") below, 2.5
2
mm (9
/
") at the sides and 450 mm (17
1
8
boiler casing must be allowed for servicing.
BOTTOM CLEARANCE
Bottom clearance after installation can be reduced to 5 mm
This must be obtained with an easily removable panel, to
enable the system pressure gauge to be visible and to provide
the 100 mm clearance required for servicing.
SERVICE REQUEST FUNCTION
When the boiler has been installed for more than 1 year the
following message will appear on screen:
Press "Restart" to clear this message.
ESCAPE OF GAS
Should a gas leak or fault be suspected contact the
National Gas Emergency Service without delay.
Telephone 0800 111 999.
1.7
TROUBLESHOOTING
NO HOT WATER
Ensure that the mains power
is turned on. If a Boiler symbol
is shown On the display then
press Mode until either Ready
or On is shown underneath the
Boiler Symbol. If a Tap symbol
is shown on the display then
press Mode until either Ready or
On is shown underneath the Tap
symbol.
Ensure that the Hot Water Timer
is On & the Cylinder Thermostat
is calling for heat."?
YES
If fault persists contact Ideal
Customer Service Helpline if your
appliance is under warranty or a
Gas Safe Registered engineer
otherwise.
Contact a Gas Safe Registered
Engineer
6
/
") at the front of the
3
4
Ensure that;
- All naked flames are extinguished
- Do not operate electrical switches
- Open all windows and doors
CLEANING
For normal cleaning simply dust with a dry cloth. To remove
stubborn marks and stains, wipe with a damp cloth and finish off
with a dry cloth. DO NOT use abrasive cleaning materials.
MAINTENANCE
The frequency of servicing will depend upon the installation
condition and usage but should be carried out at least annually
by a Gas Safe Registered Engineer.
NO CENTRAL HEATING
Ensure that the mains power is
turned on. If a Boiler symbol is
shown On the display then press
Mode until either Ready or On
is shown underneath the Boiler
Symbol. If a Radiator symbol is
shown on the display then press
Mode until either Ready or On is
shown underneath the Radiator
symbol.
Ensure that the Central Heating
NO
timer is On and that the room
thermostat is turned up.
Does the boiler operate and
provide central heating?
YES
Check the time settings on the
programmer are as you require
and adjust if necessary
Contact a Gas Safe Registered
Engineer
Service Due
[Telephone Number]
Restart
Menu
Mode
NO HOT WATER OR CENTRAL
HEATING
Ensure that the mains power is
switched on. If there is a boiler
symbol on the display then press
Mode until Ready or On is shown
under the Boiler symbol. If a
Radiator symbol is shown on the
display then press Mode until
Ready or On is shown underneath
the Radiator symbol.
Does the boiler have a display
showing on the front control
panel?
NO
See boiler "Display Functions"
section
Contact a Gas Safe Registered
Engineer
NO
YES
User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logic+ system2 s18Logic+ system2 s24Logic+ system2 s30

Table of Contents