• Do not stare into the beam • Laser module: corresponds to DIN EN 60825-1: 2014 Class 2 (<1mW / 635nm) • Laser output point trumpet and parabolic mirror: Laser output point Testo Sensor LD basic V1.01 EN Seite 3 von 22...
The accumulator and the appliance can now be disposed of separately 5 Intended use The Testo Sensor LD basic is a leak detector for quick and reliable leak detection in/on compressed air systems. It is solely designed and constructed for the intended use described here and may only be used for this purpose.
Technical data 6 Technical data Testo Sensor LD basic Dimensions hand-held 263 x 96 x 280 mm (with preamp module and acoustic housing trumpet) 0.55 kg with preamp module and acoustic trumpet, Weight complete set in case approx. 3.0 kg...
Max. output power: <1mW @ 630-660nm Complies with 21 CFR 1040.10 and 1040.11except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8,2019 Label position 8900 0402 Testo Sensor LD basic V1.00 EN Seite 6 von 22...
3.5" TFT colour display with touch panel USB Connection Plug-in connection for Foil keypad (4 buttons) power supply (battery charger socket) Save button On/Off button Volume (+/-) 3.5mm jack for the headphone Testo Sensor LD basic V1.01 EN Seite 7 von 22...
Average distance to pipe/component 0.2 - 6 m Short distance to pipe/component 0.05 m • • Low interfering noise Pipe/component freely accessible • • Leakage freely accessible Pipes and components to be inspected are very close together Testo Sensor LD basic V1.00 EN Seite 8 von 22...
Ultrasound levels can be understood as a "loudness" of the leakage. With the “Sensitivity" button, the sensitivity of the Testo Sensor LD basic can be adjusted to the environment, which strongly influences the acoustic behaviour of the device and increases or decreases the valid value range.
Attention: Please use no pens or other objects with sharp edges! The foil can be damaged! 11.1 Initialization After switching on the Testo Sensor LD basic, the initialization takes place and then switch to leakage display Testo Sensor LD basic V1.00 EN...
Bar graph of Signal level Laser „On“ Icon Date/ Time and battery Settings menu condition indicator Sensivity level button Date / Time: Battery condtion indicator Battery condition: Power supply connected and battery is charging: Testo Sensor LD basic V1.00 EN Seite 11 von 22...
Settings 11.3 ^Settings menu Testo Sensor LD basic The operation is largely self-explanatory and menu-driven via the touch panel. The selection of the respective menu items occur via short "tapping" with the finger or a soft round pen. Attention: Please use no pens or other objects with sharp edges! The foil can be damaged! Before the leakage search is started, the device must be configured.
UTC, you can set the correct time all over the world. The summer and wintertime switchover is realized by pushing the Daylight Saving button. Testo Sensor LD basic V1.00 EN Seite 13 von 22...
11.3.3.1 System update If required, there is the possibility for the Testo Sensor LD basic to download a firmware via the USB stick. The file must then be stored on the USB stick and transferred to your device as described below.
Bevor the settings are changed to the production default settings a safety prompt is displayed and must be confirmed by pressing the button „Yes“. If needed with „Reboot System“ the Testo Sensor LD basic could be started(reboot) here. 11.3.4 Calibration of touchpanel Settings ➔...
39%, after that a "normal" function operation is possible. Important: If the Backlight dimming after button is not activated, then the Backlight stays permanently on, in the currently set brightness. Testo Sensor LD basic V1.00 EN Seite 16 von 22...
(for one or two seconds) to cancel. 11.3.7 About Testo Sensor LD basic Settings ➔ About Testo Sensor LD basic *** About *** Brief description of the Hardware Software Version, as well as the...
Symbol „CHG“ is displayed during charging. The Testo Sensor LD basic checks the charging status of the battery and starts the charging process automatically if necessary. To protect the Li-ION accumulator of exhaustive discharge the device is switching off automatically if a cell voltage of 6,4V will be reached.
Scope of delivery 13 Scope of delivery Testo Sensor LD basic is available either as a single unit or in a set. The set contains all the components and accessories that are protected in a rugged and shock-resistant transport case.
Appendix 14 Appendix In the appendix on the following pages you will find the Test Report of the Li-ion batteries used. 14.1 Report UN 38.1 Testo Sensor LD basic V1.01 EN Seite 20 von 22...