When the installation is completed remount the cover panel and check:
• That the drum is empty.
• That the machine operates by connecting the power to the machine and start a program with heat.

7.5 Electrical connections

Heating alternative
Main voltage
Electric heated
220–240V 1 ~
machines
220–230V 3 ~
240V 3 ~
380–415V 3N ~
440V 3 ~
480V 3 ~
115V 3 ~
Gas- and Steam
220–240V 1 ~
heated machines
220–240V 3 ~
380–415V 3N ~
440V 3 ~
480V 3 ~
Machines with heat
220–240V 1 ~ / 1N ~
pump
380–480V 3 ~ / 3N ~
Machines with heat
380–415V 3 ~ / 3N ~
pump with DSC
(Drum Speed
Control)
* Total power and recommended fuse does not depend on the heating power in those cases.
Installation manual
Hz
Heating power
kW
50/60
6.0
50/60
9.0/13.5
50/60
9.0/13.5
50/60
9.0/13.5
50/60
9.0/13.5
60
9.0/13.5
60
13.2
50/60
50/60
50/60
50/60
60
50/60
50/60
50/60
Total power
kW
7.0
10.0/14.5
10.0/14.5
10.0/14.5
10.0/14.5
10.0/14.5
14.3
*
1.2
*
1.0
*
1.0
*
1.0
*
1.0
*
5.5
*
6.5
*
6.5
37
Recommended fuse
A
32
32/50
25/32
16/25
16/20
16/20
80
10
10
10
10
10
25
10
13