7.2 Machine connection with ferrite

7.2.1

Machines with AFC or DSC

To obtain approved level of EMC, it is mandatory to use the ferrite which is enclosed with machines equipped with
AFC (adaptive fan control) or DSC (drum speed control). (Note that this is only valid for those machines).
Before connecting to the machine, the protective earth (PE) wire shall be wrapped around the ferrite.
Prepare the power cord by making sure the protective earth (PE) wire is longer than the other wires according to the
table.
Wire size
AWG14 or 2,5 mm
AWG12 or 4 mm
AWG10 or 6 mm
AWG8 or 10 mm
AWG6 or 16 mm
AWG4 or 25 mm
When the power cord has been prepared according to the table, wrap the protective earth (PE) wire through the fer-
rite and then connect all wires according to the following connection options.
Installation manual
2
2
2
2
2
2
L1
T1
L
280 mm
280 mm
300 mm
330 mm
400 mm
490 mm
L2
L3
N
N1
T2
T3
x times through
x 5
x 5
x 5
x 5
x 5
x 5