8.4 Electrical connections
Electrical connections
Heating alternative
Electric heated
Gas heated
1.
Total power and recommended fuse does not depend on the heating power in those cases.
Electrical connections
Heating alternative
Machines with heat pump
1.
Total power and recommended fuse does not depend on the heating power in those cases.
Installation manual
Main voltage
220–240V 1/1N~
220–240V 3~
380-415V 3N/3~
440V 3~
480V 3~
115V 3~
220-480V 1/1N/3/3N~
Main voltage
220-240V 1N~
380-415V 3N~
Hz
Heating power
kW
50/60
6.0/8.0
50/60
6.0/8.0
50/60
6.0/8.0
60
6.0/8.0
60
6.0/8.0
60
4.1
1
50/60
Hz
Heating power
kW
1
50
1
50
Total power
Recommended
kW
fuse
A
6.4/8.4
32/50
6.4/8.4
20/25
6.4/8.4
10/16
6.4/8.4
10/16
6.4/8.4
10/16
4.5
25
0.4
10
Total power
Recommended
kW
fuse
A
2.3
13
2.5
10
31