6.3.4 Elevator Control Settings

Setting Remote Control
Steps:
1. Click Elevator Control Settings -> Remote Control to enter the Remote Control page.
2. Check the floor button that need to control (multiple choice is allowed).
Or click Select All to check all floor buttons.
3. Click the control button in the interface to control the floor button. You can select Disable,
Controlled, Free, Open, Visitor (Call Elevator by Visitor), or Call Elevator (Call Elevator by
Resident).
Disable: You cannot go to the selected floor.
Controlled: You should swipe the card to press the selected floor button. And the elevator can
got to the selected floor.
Free: The selected floor button will be valid all the time.
Open: The floor button will be valid for a period of time.
Visitor: The elevator will go down to the first floor. The visitor can only press the selected floor
button.
Call Elevator: Call the elevator to the selected floor.
Notes:
 The elevator cannot be controlled by other client software if the elevator status changes.
 Only one client software can control elevator each time.
 The client software which has controlled the elevator can receive the alarm information and
the elevator status. Other client software cannot.
represents the floor button is disabled;
represents the floor button is free.
Setting Floor Parameters
Steps:
1. Click Elevator Control Settings -> Floor Parameters to enter the Floor Parameters interface.
Main Elevator Controller User Manual
24
represents the floor button is controlled;